Roof Down Slope Hole Size
Degree
Of Slope
Secure Temp
ASHT+
Nova Temp
HT6103+
AC
Roof
Pitch
10”
10”
0 * 16-3/8” (416 mm) 17” (432 mm)
2/12 16-5/8” (422 mm) 17-1/4” (438 mm)
4/12 17-1/4” (439 mm) 18” (457 mm)
6/12 18-3/8” (466 mm) 19” (482 mm)
8/12 19-3/4” (500 mm) 20-1/2” (520 mm)
10/12 21-3/8” (542 mm) 22-1/8” (562 mm)
12/12 23-1/8” (588 mm) 24” (611 mm)
Table 3 * Cross Slope Hole Size
CHIMNEY MODEL AC
Collar
Chimney
Flashing
Figure 32
Figure 33
OFFSET CHIMNEY INSTALLATION
After reaching the location requiring the elbow,
proceed as follows. The minimum chimney
height when using elbows is:
OFFSET CHIMNEY INSTALLATION
The minimum chimney height when using elbows is:
Minimum Chimney Height
When Using Elbows
Fireplace Model Cambria™
Chimney Model Secure Temp
ASHT+
/ Nova
Temp
HT6103+
/ AC
Vertical Installation 15 feet (4.57 meters)
Two (2) Elbows 18 feet (5.49 meters)
Four (4) Elbows 20 feet (6.10 meters)
Table 4
Note: Must return to vertical before penetrating
ceiling or floor.
After reaching the location requiring the
elbow, proceed as follows:
Secure Temp
ASHT+
/ Nova Temp
HT6103+
Chimneys
1. Install the first elbow; turn it in the required
direction. Fasten it to the chimney with
the three (3) 1/2” (13 mm) metal screws
provided with the elbow.
2. Install the necessary chimney lengths to
achieve the required offset. Lock the chimney
lengths together: it is recommended to use
three (3) 1/2” (13 mm) screws. If the offset
length is made of two (2) chimney lengths
or more, use an offset support halfway up
the offset. If penetrating a wall, install a wall
radiation shield (see Figures 36 and 37).
3. Use another elbow to turn the chimney
vertically. Secure the elbow, using three
(3) 1/2” (13 mm) screws (provided with the
elbow).
4. Use a plumb-bob to line up the center of
the hole. Cut a hole for the chimney in the
ceiling/floor. Frame this hole as described
previously (see Chimney Installation Instruc-
tions on Page 17).
5. From below, install a firestop (See Figure
30a).
6. A support (ST or SO) must be used on the
first 15 feet section (5 m).
7. Continue with the regular installation.
AC Chimney
1. Install the first elbow. Turn it in the required
direction. To lock it in place, turn 1/8 of a
turn. Fasten the straps attached to the elbow
to the surrounding frame, using nails or
drywall screws (Figure 35).
2. Install the necessary chimney lengths to
achieve the required offset. Lock the chimney
lengths together. If penetrating a wall, use
a wall radiation shield.
3. Use another elbow to turn the chimney
vertically. Lock it to the chimney. Fasten
the straps attached to the elbow to the
surrounding framing using nails or drywall
screws.
4. Use a plumb-bob to line up the center of the
hole. Cut a hole for the chimney in the ceiling.
Frame this hole as described previously.
5. From below, install a radiation shield (see
Figure 30b).
6. Continue with the regular installation.
(EL) Replace firestop with radiation shield (done 1-9-08)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
19