Lennox Hearth 32FS Stove User Manual


 
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
5
Up to * 6” (153 mm)
6”
(153 mm)
min.
6”
(153 mm)
min.
6” (153 mm)
min.
Figure 1 - Floor Protection Requirements
* Notes:
When installed at clearances less than 6”, the floor
protection is only required to extend to the wall. Refer to
Page 4
for chimney/venting floor protection requirements and
recommendations.
Rear
Front
Top View
Floor Protector
Standard residential or manufactured home installation. These appliances
require the following minimum clearances to combustibles:
Figure 2
Combustible
Combustible
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
NE PAS ENLEVER CETTE ÉTIQUETTE DÉGAGEMENT MINIMUM POUR LES
MATÉRIAUX COMBUSTIBLES
Freestanding Stove Installation / Installation Du Poêle Autonome
Manufactured (Mobile) Home Or Residential Installation / Installation Résiden-
tielle Ou Dans Une Maison réfabriquée (Mobile)
A - Side wall to unit 4” (102 mm)
B - Back wall to unit 2” (51 mm)
C - Side wall to unit Corner 1” (25 mm)
D - Max. Depth of Alcove
u 24” (610 mm)
E - Flue to Wall
v 3" (76mm)
u Minimum Alcove Measurements - Height 48” (1220 mm) x Width 31”
(788 mm) x Maximum Depth 24” (610 mm)
v See vent manufacturer to verify clearances
Table 1
Combustible
Rear Wall or Alcove - Clearance to Combustibles
Figure 3
Corner - Clearance to Combustibles
B
A
*E
D
A
E*
C
C
Combustible
Combustible
IMPORTANT
Minimum clearances specified may not allow
for ease of operation and maintenance (please
take this in to account when planning the instal
-
lation). If installed to the minimum clearances,
removal of the appliance may be necessary for
servicing.
Recommended clearance zone from the front
of the appliance to combustibles is 4 feet mini
-
mum.
Clearances to combustibles for the appliance
can only be reduced by means approved by the
regulatory authority.
CLEARANCES - Montage™ 32FS
*Note: Refer to pipe Manufacturer's installation
instructions for minimum pipe clearances.
*Note:
Refer to pipe Manufacturer's installation
instructions for minimum pipe clearances.