5) Position the remote temperature/humidity sensor in the desired location, ensuring that the indoor
weather station can receive the signal.
II. THE INDOOR WEATHER STATION
The indoor weather station can be mounted in several ways:
With the use of screws
Using its foldout stand
A. MOUNTING WITH SCREWS
1) Fix a screw (not included) into the desired wall, leaving approximately
3/16 of an inch (5mm) extended from the wall.
2) Place the indoor weather station onto the screw using the hanging hole
on the backside.
3) Gently pull the indoor weather station down to lock the screw into place.
B. FOLDOUT TABLE STAND:
The foldout table stand leg is located on the backside.
1) Pull the stand out from the bottom center edge of the weather station,
below the battery compartment.
2) Once the foldout table stand is extended, place the weather station in an
appropriate location.
TROUBLESHOOTING
NOTE: For problems not solved, please contact La Crosse Technology.
Problem: No reception of WWVB time signal.
Solution: 1) Wait overnight for signal.
2) Be sure indoor weather station is at least 6 feet from any electrical devices, such as televisions, computers, or other
radio-controlled clocks.
3) Remove batteries for five minutes, reinsert and leave the unit alone overnight without pressing buttons.
4) If there are still problems, contact La Crosse Technology.
Problem: Hour is incorrect (minute and date are correct).
Solution: Be sure correct time zone and daylight saving time settings are selected.
Problem: The LCD is faint.
Solution: 1) Set the LCD contrast to a higher number.
2) Replace the batteries
Problem: No outdoor temperature/humidity is displayed.
Solution: 1) Remove all batteries, reinsert into remote temperature/humidity sensor first, then the indoor weather station.
2) Place the remote temperature/humidity sensor closer to the display.
3) Be sure all batteries are fresh.
4) Place the remote temperature/humidity sensor and indoor weather station in position so the straight-line signal is not
passing through more than two or three walls.
Problem: Temperatures do not match if units are placed next to each other.
Solution: Each temperature/humidity sensor is manufactured to be accurate to within 2 degree plus or minus and under normal
conditions, so two sensors could be as much as 4 degrees different. However, the difference can be exaggerated further
because the sensors are designed for different working environments. The indoor temperature sensor is less responsive
to ambient air currents because of the shielding effect of the display's case. In addition, the case can act as a heat sink to
absorb and store heat from external sources (i.e. handling of the case or radiant heat). Also, the much greater range of
the remote temperature/humidity sensor requires a different calibration curve than the indoor range. Error is usually
greater at the extreme ends of a range, making it harder to compare different ranges with different curves. Under non-
MAINTENANCE AND CARE INSTRUCTIONS
Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units.
Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents; they may mark the displays and
casings.
Do not submerge in water.
Immediately remove all low powered batteries to avoid leakage and damage.
Opening the casings invalidates the warranty. Do not try to repair the unit. Contact La Crosse Technology for repairs.