Conversion from Liquid Propane (LP) to Natural Gas (NG)
Installation of the regulator
1.Turn off the main gas supply valve.
2.Unplug grill or disconnect power.
3.Disconnect 20 lb LP gas fuel tank (if present).
4.Turn off all burner control valves.
5.Remove the 20 lb LP gas fuel tank (if present) from the grill
cart.
6.Use an adjustable wrench to remove the LP regulator from
the manifold.
Make Gas Connection
1. A combination of pipe fittings must be used to
connect the grill to the existing gas line.
The 10 ft (3.0 m) PVC flexible gas supply hose design-
certified by CSA must be used.
Pipe-joint compounds suitable for use with Natural gas
must be used. Do not use Teflon®† tape.
There must be a certified manual shutoff valve in the
gas supply line near the grill for easy access.
2.Connect the brass connector on one end of the 10 ft
(3.0 m) PVC flexible gas supply hose (supplied) to the
Natural gas pressure regulator.
3.Connect the quick connector on the other end of the
10ft (3.0 m) PVC flexible gas supply hose to the rigid
Natural gas supply pipe.
7.Use an adjustable wrench to install the Natural gas
regulator hose to the manifold and secure. Attach the
Natural gas regulator to the side panel inside the grill cart
with the two screws that are preassembled on the
regulator.
Change Grill Burner Valve Orifices
1.Remove the grates and flame tamers.
2.Remove the screws and pin that hold the burner in
place. Set the screws and pin aside. Remove the
burner from the grill by lifting the burner out.
A.Side panel
B.Manifold
C.10ft. (3.0m) PVC gas hose
D.Natural gas pressure regulator/hose assembly
5