Kenmore 625.38817 Water System User Manual


 
SECTION 5 SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
S
C
T
N
_JJJJJJJJJJJJJJJJ=
_JJJJJJJJJJJJJJJJ=
WIRING SCHEMATIC
l BACK OF TIMER I
(PWA)
AC INPUT POS / TURBINE MOTOR
Turbine _ gm O_ltl'NO Position
Sensor bm Switch
°NC
valve
motor
FAC
dis
J
SALT
1-800_426-9345
PRESS FOR
HOLD FOR _M
RECHARGE button SELECT button DOWN button
Low salt
indicator
-_ UP button
Keep this manual with your water softener. If repairs are needed, the service technician must have
the information on the following 8 pages. For telephone assistance, call toll free, 1-800-426-9345.
ALWAYS MAKE THESE INITIAL CHECKS FIRST
_q Does the time display show the correct time of
day?
--If display is blank, check power source to the
softener.
-- If time is flashing, power was off for over 6
hours. The softener resumes normal operation
but regenerations occur at the wrong time.
- -If an error code (Example: Err03) shows in the
faceplate display, go to AUTOMATIC ELEC-
TRONIC DIAGNOSTICS.
Plumbing bypass valve(s) must fully in ser-
_e
vice position.
outlet pipes must connect to
The inlet and the
softener inlet and outlet respectively.
m zz /!
Is the transformer plugged into a live,
grounded wall outlet, and the power cable fas-
tened securely to the controller?
_The valve drain hose must be free of kinks and
sharp bends, and not elevated over 8 ft. above the
floor.
Remove the top cover and salt tank cover.
Is in storage tank?
there salt the
_Is the brine connected? flow
tubing (See
water
diagrams).
Is the brine valve float set right? (See page 5-4).
Press the SELECT button three times to display
the hardness setting. Be sure it is the correct set-
ting for the household's water supply. (Make a
hardness test of the raw water and compare with
the hardness setting. Also test a soft water sam-
ple to verify if a problem exists.) Press the SE-
LECT button twice more to return to present time
in the display.
If you do not find the problem after making initial
checks, do the MANUAL INITIATED ELEC-
TRONIC DIAGNOSTICS, and the MANUAL AD-
VANCE REGENERATION CHECK.
5-1
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line