Kenmore 625.38811 Water System User Manual


 
SECTION1 WATER SOFTENER START UP
C. PROGRAM THE TIMER
m
SET WATER HARDNESS NUMBER I_ SET RECHARGE (REGENERATION) TIME
m
Press the SELECT button once to display 25
(flashing) and HARDNESS.
The grains per gallon (gpg) hard-
ness of your water supply is on
your water analysis report. Be
sure to enter water test results on
page A, for future reference.
2S
If your water supply contains iron, compensate for
it by adding to the water hardness number. For ex-
ample, assume your water is 20 gpg hard and con-
tains 2 ppm iron. Add 5 to the hardness number for
each 1 ppm of iron. In this example, you would use
30 for your hardness number.
20 gpg hardness
2 ppmiron x 5 = 10 +10
(times) 30 HARDNESS NUMBER
Press the UP / DOWN buttons to set your water
hardness number in the display. The DOWN button
moves the display to 1. The UP button moves the
display to the highest setting (see maximum setting
for your model in the specifications).
Note:
Each press of the UP / DOWN button changes the
display by i between i and 25. Between 25 and the
highest number, the display changes 5 at a
time... 25, 30, 35, etc. Holding the UP or DOWN but-
ton in changes the display twice each second.
Press the SELECT button to display 2:00 AM
(flashing) and RECHARGE TIME.
At the 2:00 AM recharge time _'_]0_"
setting, the softener begins re- '_
generation (see pages 2-3 and
2-4) at 2:00 AM, ending no later
than 4:00 AM. This is a good time in most house-
holds because water is not being used (see Auto-
matic Bypass, page 2- 4). If a different recharge time
setting would be better for your household, do the
following.
Press the UP / DOWN buttons to set the desired
recharge starting hour. Be sure to observe the AM-
PM as you did when setting the present time of day.
Note:
Each press of the UP / DOWN buttons changes the
display i hour. Holding the buttons in changes the
display twice each second.
Press the SELECT button once again, to com-
plete initial programming, and RECHARGE TO-
NIGHT shows in the display.
IF YOU NEED HELP PROGRAMMING THE TIMER, CALL TOLL FREE,
NUMBER 1- 800 -426 - 9345.
SEE PAGE 2-1 FOR OTHER FACE PLATE TIMER FEATURES.
1-4
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line