Kenmore 625.38376 Water System User Manual


 
TROUBLESHOOTING
VALVE POSiTiON iNDiCATORS:
Depending on the valve position, the following indica-
tors show in the display:
indicator Valve Position
Serv ..................................... Service
Fill........................................ Fill
Brine .................................... Brining/Brine Rinse
Bkwsh .................................. Backwash
Rinse ................................... Fast Rinse
When the valve is rotating from one cycle to another,
both indicators flash. For example, if the valve is in
transition between fill and brining, both Fill and Brine
flash. Upon reaching brining position, Fill goes off and
Brine is on steady. The time display shows the minutes
of the cycle remaining.
'_ Motor
Housing
Position Switch
Turbine
Valve Outlet
Turbine
Support
and Shaft
FiG. 62
NOTE: If the faceplate is left in a diagnostic display
(or a flashing display when setting times or hard-
hess), present time automatically returns if a button
is not pressed within 4 minutes. To return to the
diagnostic display, repeat step 1.
OTHER INFORMATION
While in this diagnostic screen, the following information
is available and may be beneficial for various reasons.
This information is retained by the computer from the
first time electrical power is applied to the faceplate.
Position markers
(Valve in service)
FiG. 63
Press and hold the UP button to display the number of
days this faceplate has had electrical power applied.
Press and hold the DOWN button to display the num-
ber of regenerations initiated by this faceplate since
the code number was entered.
Press the RECHARGE button to advance the valve to
each position and observe the switch and position
indicators to verify component operation, or to possi-
bly isolate a defect.
Press and hold the SELECT1 button for 3 seconds
until a model code shows in the display, see Fig. 64.
TIMER PWA REPLACEMENT
Be sure the valve is in service position when replac=
ing the timer PWA (observe valve cycle indicator). If
after installing and programming the replacement timer
PWA, the valve is not in service position, do the following
to assure correct cycle orientation, or timing, between the
faceplate and valve.
Use the MANUAL ADVANCE procedures with the
RECHARGE NOW button, advance through the recharge
cycles until the valve stops in service position, and
RECHARGE no longer flashes in the display.
This code identifies the softener nominal capacity
size. If the wrong number shows, the softener will
operate on incorrect data. Do the following as needed.
If the correct model code (H 32) shows: Press the
SELECT1 button to return to the present time display.
To change the number: Press the UP or DOWN but-
ton until the correct model code (H 32) shows. Then,
press the SELECT1 button and reset the timer.
NOTE: The valve motor may automatically drive
through several valve positions while searching for
service. If an error code occurs, unplug the trans-
former, then plug in again.
,,
FiG. 64
Questions? Call The Kenmore Water Line 1-800-426-9345