4. Press SELECT again to display the "Recharge Days"
screen.
DAY _ DAY ]
RECHARGE RECHARGE
Default Display Example:
Set to 4 days maximum
between regenerations
Figure 28
MAXIMUM DAYS BETWEEN REGENERATIONS: The
electronic controller automatically determines regen-
eration frequency. This provides the greatest operat-
ing efficiency and, under most conditions this feature
will be left in its default mode. However, you can
set this feature to force a regeneration every set
number of days. You may want to do this if, for
example, your water supply contains iron and you
want the softener to regenerate at least once every
few days to keep the resin bed clean. Use the f
UP or V DOWN buttons to change the number of
days (up to 6).
5. Press SELECT again to display the "97%" screen.
nEE
UFF
RECHARGE RECHARGE
Figure 29
97°/o FEATURE: The 97% Feature can save salt and
water by regenerating when 97% of the softener's
capacity has been used up. With this feature ON,
the regeneration can occur at any time (whenever
the system has reached 97% of its capacity). The
default is OFF. If this feature is desired, turn it on by
pressing the UP f button.
6. Press SELECT again to display the "12 or 24 hr"
screen.
AM
r
TIME
C! r
Figure 30
12 OR 24 HOUR CLOCK: All time displays are shown
in standard clock time (1 to 12 AM; and 1 to 12 PM)
at the 12 hr default setting. If 24 hour time format is
desired, set to 24 hr by pressing the UP f button.
7. Press SELECT again to display the alternating screens
shown in Figure 31.
O0
Bk wsh
TIME
MIN
n}
a_ MIN
Bk wsh
TIME
Figure 31
BACKWASH & FAST RINSE TIMES: If you experience
salty tasting water after regeneration, you may need
to increase the backwash and fast rinse times. The
cycle times during regenerations are determined by
the softener's electronic controller. However, you may
increase the backwash and fast rinse times, in 1
minute increments. If you wish to increase the back-
wash time, use the f UP button to add up to 15 min-
utes to the backwash time. Then press SELECT to dis-
play the alternating screens shown in Figure 32.
w
H I1
OOM'N
Rinse TIME
0}
U _N
Rinse TIME
Figure 32
If you wish to increase the fast rinse time, use the
f UP button to add up to 15 minutes to the fast
rinse time.
8. Press SELECT to return to the normal run (time of
day) screen.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com