Kenmore 625.3835 Water System User Manual


 
INSTALL GROUNDING CLAMP
The house cold water pipe (iron or copper) is often used
to ground all electrical outlets in the home. To maintain
this ground, use the ground clamp kit included in the
parts bag. Install the ground clamp across the inlet
and outlet metal pipes (see Fig. 14). Make sure good
contact is made between the pipe and the clamps.
INSTALL COVERS
After installing your water softener, put the covers on.
Angle the covers so the top cover clips onto the back
first, then bring down in front and clip on the tabs
inside the rim and lower the salt lid closed (See Fig. 5).
CONNECT TO ELECTRICAL POWER
The softener works on 24 volt, 60 Hz electrical power.
The included transformer changes standard 120 volt AC
house power to 24 volts. You must plug the water soft-
ener's transformer into a grounded, 120 volt outlet only.
Be sure the outlet is always "live" so it cannot be
switched off by mistake.
NOTE: The electrical outlet you plug the transformer
into must be indoors, protected from weather.
RESTART THE WATER HEATER
Turn on the gas (or electric) supply to the water heater
and light the pilot.
YOUR PLUMBING INSTALLATION AND
ELECTRICAL WORK ARE NOW COMPLETE.
METAL PIPE GROUNDING
Ground
Clamp "'_1
(2 halves)
Screw with J
Iockwasher
& nut
TO
Valve Inlet
8
FROM
Valve Inlet
Figure 14
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
11