Kenmore 625.348460 Water System User Manual


 
TIME
RECHARGE
TIME TIME
SERVICE TECH. INFORMATION
SECTION 5
21
5A. TROUBLESHOOTING
CORRECT
SWITCH
DISPLAYS
VALVE CYCLE STATUS
– –
Valve in service, fill, brining,
backwash or fast rince position
–P
Valve rotating from one posi-
tion to another
C. While in this diagnostic screen, the following
information is available and may be beneficial
for various reasons. This information is reĆ
tained by the computer from the first time elecĆ
trical power is applied to the face plate.
-- Press to display the number of days this
face plate has had electrical power applied.
-- Press to display the number of regeneraĆ
tions initiated by this face plate since the SR
code number was entered.
2
. Press Select to advance to the following
alternating displays.
This setting controls the length of the backĆ
wash cycle (regular recharge backwash, and
the CLEAN feature backwash if set to ON). A
longer backwash is beneficial if supply water
is dirty, or contains iron. The time is adjustable
up to 5 minutes. Use the UP or DOWN button
to set.
3
. The next press of the SELECT button displays
an AUTO RECHARGE screen.
For this model, the AUTO RECHARGE display
must show. If anything other than AUTO
shows, press a UP or DOWN button until it
does show.
4
. Press SELECT once again to display 12 hr, TIME.
At this setting, display times are shown in stanĆ
dard clock time. If set to 24 hr, using the UP or
DOWN button, display times will be in military
time, 0100 (1:00 AM) to 0000 (midnight).
5
. Press the SELECT button and hold 3 seconds
until
. . .SC21 shows.
This code identifies the softener nominal capacity
size. If the wrong number shows, the softener will
operate on incorrect programming. Do the
following as needed.
RETURN THE PRESENT TIME DISPLAY - Press the
SELECT button.
CHANGE THE SR NUMBER - Press the UP or DOWN
button to display correct number; press SELECT, and
reset the timer.
NOTE:
If the face plate is left in a diagnostic display (or a flashing
display when setting times or hardness), time of day
automatically returns if a button is not pressed within 4