SECTION 5 SERVICER'S TECH. INFORMATION
5A. TROUBLESHOOTING
KEEP THIS MANUAL WITH YOUR WATER SOFTENER. IF REPAIRS ARE NEEDED, THE SERVICE
TECHNICIAN MUST HAVE THE INFORMATION ON THE FOLLOWING PAGES.
24VAC
WIRING SCHEMATIC
NC
tt
NO
N
DOWN
UPbumm
,/
ON_DFF- HOUDburn SELECTimuan
ALWAYSMAKE THESE INmAL CHECKS FIRST
1. Does thetimedisplayshowthe correctUmeofday?.
...If display is blank, check power source to the
soRener.
...If time isflashing, powerwas off for over 6 hours.
The softener resumesnormaloperationbutregen-
erationsoccurat the wrongtime.
...If anerrorcode (Example:Err03)showsinthe face
plate display,go to AtJTO_C ELECTRONIC
DIAGNOSTICS.
2. Plumbing bypass valve(s) must be in Full Service
position.
3. The inletandoutletpipesmustconnect tothesoftener
inletand outletrespectively.
4. Isthe transformerpluggedintoa qive",groundedwall
outlet,and the powercablefastenedsecurely?
z
5. The valvedrainhose mustbefree ofIdnksandsharp
bends,and notelevatedover8 ft. abovethe floor.
REMOVE THE TOP COVER AND SALTTANKCOVER
6. istheresaltinthestoragetank?
7. Is the brine tubing connected? (See water flow
diagrams).
8. Isthe brinevalvefloatsetright?(See page 22).
9,
Press the SELECT button2 times to display the
hardnesssetting.Besureitisthe correct settingforthe
households watersupply.(Make8 hardnesstestofthe
rawwaterandcomperewiththehardnesssetUng.Also
test a softwatersampieto verifyifa problemexlsts.]l
Press SELECT 3 times to ratum the present time
display.
ffyoudonotitnd theproblemaftermakinginitialchecks,do
the MANUAL INmATED ELECTRONIC DIAGNOSTICS,
andthe MANUALADVANCE REGENERATION CHECK.
19