SERVICE TECH. INFORMATION
SECTION 5
29
5E. WATER FLOW THROUGH THE SOFTENER VALVE
BRINING AND BRINE RINSE CYCLES
After fill, timer/switch action allows the motor to turn the rotor and disc into BRINING position.
Water flow is directed to the nozzle. Suction, created by the nozzle and venturi, draws brine from
the salt storage tank and injects it into the resinbed via the bottom distributor.Flow continuesout
the top distributor and to the drain. Hard water is available at the valve outlet.
Whenthebrinevalveclosestoendbrinedraw,waterflowcontinuesinthe samedirectionstoslow-
ly RINSE brine from the resin bed and to the drain.
drain
brine from
salt stor-
age tank
nozzle
venturi
bypass hard water
to valve outlet
from Valve Inlet
(hard water)
BACKWASH CYCLE
Timer/switch action again allows the motor
to turn the rotor & disc to place the valve in
BACKWASH, stopping water flow to the
nozzle.Waterisrouteddown andoutthebot-
tom distributor, up through the bed, and out
the top distributor to the drain. The fast flow
(controlledbya flowplug inthe drainfitting)
flushes dirt, sediments, iron deposits, re-
maining brine and hardness to the drain.
drain
flow plug
bypass hard water
to valve outlet