Kenmore 625.348321 Water System User Manual


 
SERVICE TECH. INFORMATION
SECTION 5
23
5B. REGENERATION CYCLE TIMES
SEE REGENERATION TABLE ON PAGE 20, AND SPECIFICATIONS, PAGE 21.
CYCLE FLOW RATES (GALLONS PER MINUTE)
FILL (flow to salt storage tank) 0.3 (1.1 liters)
BRINING .16 (.6 liters)
BRINE RINSE
(
f
l
o
w
t
o
d
r
a
i
n
)
.11 (.4 liters)
BACKWASH
(
f
l
o
w
t
o
d
r
a
i
n
)
1.8 (6.8 liters)
FAST RINSE 1.8 (6.8 liters)
TO SET DOUBLEBACKWASH(Softenerhas abackwash and fastrinse cycle before brining, and
after brining, which is beneficial on some kinds of iron bearing water):
USE BUTTONS £ (SET/CLEAR), and ¡ (PRESENT TIME AND DAY)
1. Press and hold £ entire display comes on.. . . . . . . . . . . . . . .
" Press ¡ to display 3 dashes
" Press £ to display dbl
" Press ¡ to display 18:88
2. Press £ to return present time.
REPEAT ABOVE STEPS TO CANCEL DOUBLE BACKWASH.
CYCLE SEQUENCE WITH DOUBLE BACKWASH: 1. Fill 2. Backwash 3. Fast Rinse 4.Brining/Brine Rinse 5.Back-
wash 6. Fast Rinse Return to Service
OTHER RECHARGE CYCLE TIME ADJUSTMENTS
Cycle times in specifications are factory settings. Do the following to check for correct cycle times.
NOTE: Removing from electrical power (varies from 6 to
15 hours) resets timer to factory programming.
DISPLAY MUST SHOW TIME AND DAY
1. Press and hold £ ¼entire display
comes on.
2. Press © ¼2:08 shows; meaning
#2 cycle (brining & br. rinse) and
80 minutes (8 x 10).
a. If 2:08 does show, go to step 3.
b. If other than 2:08 (2:00 to 2:15),
press £ until 2:08 shows.
3. Press © ¼3:12 shows, meaning
#3 cycle (backwash) and 12 minutes.
a. If 3:12 does show, go to step 4.
b. If other than 3:12 (3:00 to 3:30),
press £ until 3:12 shows.
NOTE: Instead of programming a double backwash, a
longer single backwash is beneficial on some types of iron
water.
4. Press © ¼4:04 shows; meaning
#4 cycle (fast rinse) and 4 minutes.
a. If 4:04 does show, go to step 5.
b. If other than 4:04 (4:00 to 4:30),
press £ until 4:04 shows.
5. Press © ¼18:88 shows.
6. Press £ ¼to return to present time and day.
TO SET MINUTE LENGTH OF FILL CYCLE (factory setting, 8 minutes)
USE BUTTONS © (RECHARGE TIME), £ (SET/CLEAR), and ¡ (PRESENT TIME AND DAY)
1. Press and hold © until FILL shows, then 16 (factory setting).
" Press £ to set the desired fill minutes
(from regeneration table).
2. Press ¡ to return present time and day.
PM
MO WE TH FR SA
RCHG
.
.
AM
TU
SU
PM
MO WE TH FR SA
RCHG
.
.
AM
TU
SU
.
.
.
.
.
.
PM
MO WE TH FR SA
RCHG
.
.
AM
TU
SU
.
.
.
.
.
.