INSTALLATION
Picka locationwhichwill allowyouto blowthe cold airinto
the area youwant. Windowsusedfor installationmust be
strong enoughto supporttheweight ofthe air conditioner.
Goodinstallationwith specialattentiontothe properposition
of the unitwill lessenthe chancethat servicewill beneeded.
Ifair conditioneris blockedbya stormwindowframe,see
step 9 on page7 before beginningto install.
HOW TO INSTALL
U SIDE CURTAINS
Insert the side curtains into the upper and lower
guides of the air conditioner. Fasten the curtains to
the unit with screws (ITEM A), as shown in FIG. 2.
ITEMA FIG. 2
_'_ FOAM STRIP
Cutthe adhesive-backed foam strip (ITEM D)to the
window width.
Removethe backing from the foam strip and attach the
foam strip to the underside of the bottom window. (FIG. 3)
L_I ATTACH L BRACKET
Install the L brackets on the outer sill with the short
side of the bracket against the back of the inner
sill. Install one L bracket 8" to each side of center
line. See FIG. 5.
• The bracket helps to hold unit securely in place.
Be sure to place bracket edge flush against back
of inner sill. See FIG. 5.
• If air conditioner is blocked by storm window
frame, see step 9.
INNER SILL
OUTER SILL ITEMA INSIDE
LINE
f
SHORT SIDE
OUTSIDE
L BRACKET
FIG. 5
DRAINAGE
First, be sure to insert the drain pipe into base pan
before installation.
The air conditioner must be installed with a slight tilt
downward (see FIG. 8) for proper water drainage.
The air conditioner will drain the excess condensed
water through the drain pipe.
FIG. 3
_'_ LOCATING UNIT IN WINDOW
Open the window and mark center line with pencil
on the center of the inner sill, as shown in FIG. 4.
INNER SILL
ROOM SIDE
FIG. 4
DRAINCAP
DRAINPIPE
_BASE PAN REAR
DRAIN _,__
FIG. 6
-6-