[i!i !!:;:_!! :;:_!:SECTION 2 HOW YOUR WATER SOFTENER WORKS
A. FACEPLATE TIMER FEATURES
I1_ TANK LIGHT
To light the inside of the salt storage tank, press the
TANK LIGHT button on the faceplate. Press the
same button again to turn the light off, or it will turn
off automatically in 4 minutes.
SALTSI_NAI
........ -1171-1 _M
- -8-- 'L I-I
5
tank lightON __
indicator _ .'_"
.... TANK
I1_ WATER FLOW THROUGH THE SOFTENER
To view the gallon (or liter) per minute water flow
rate through the softener, if not already displayed,
press the SELECT 2 button. If soft water is being
used, the flow rate to the closest 1/ 10 gallon (or li-
ters) shows. If all faucets and water using ap-
pliances are off, the display will show 0 flow.
l _1
D, 0
_ _ FLOW RATE
AVERAGE DAILY GALLONS or LITERS
Press the SELECT 2 button again to show the aver-
age number of gallons (or liters) of soft water the
household uses each day. This water usage figure is
adjusted daily by the faceplate timer. To turn this
display off, press the SELECT 2 button once more.
_'_'[_g)2q -1,I-1I-1,,,,,,,
-;--1 ,'L,O
/_ / ,nn
/2 / II- I-I
I--'--IA_o.OA,L_OA_LON_
_. RECHARGE TIME REMAINING and VALVE
POSITION INDICATORS
One of the valve position indicators (Serv, Fill, Brine,
Bkwsh, Rinse) is displayed while the softener is re-
charging (See *Note on page 2-1 if the CLEAN fea-
ture is ON). RECHARGE flashes in the display and,
beginning with Brine, the minutes of recharge re-
maining before return to service appears in place of
the present time. When the valve is moving from
one cycle to another, both position indicators are
flashing.
valve position ----_i........ recharge time
" EL S_w
indicators __ I I-I1-I_ remaining
1....
I1_ PROGRAM MEMORY
If electrical power to the softener goes off, the time
display is blank but the face plate timer keeps the
correct time for about 48 hours. When electrical
power comes on again, you have to reset the present
time only if the display is flashing. The HARD-
NESS and RECHARGE TIME never require reset-
ting unless a change is desired. Even if the timer is
incorrect after a long power outage, the softener
works as it should to keep your water soft. Howev-
er, regenerations may occur at the wrong time of
day until you reset the timer to the correct time of
day.
I_ ERROR CODE
An error code could appear in the face plate display
if a problem occurs in the softener electronics. If you
see an error code instead of the present time of day,
look at Troubleshooting page 5-2 and/or call the
Kenmore Water Line 1- 800-426-9345.