Note: After switching the unit on, the ventilator operates, but the compressor only
starts after the control lamp has flashed for 3 minutes. Cooling effect may require a
further 5 minutes. This is done as a protection mechanism to prolong compressor life.
Further information is available in the “Troubleshooting” section.
AIR CONDITIONING MODE – IN ROOM OPERATION
We recommend starting your unit early in the morning on warm days for maximum effect.
This unit has a self-evaporation system for condensation water; there is no water tank to empty. The
drainage hose MUST NOT be connected for INDOOR air conditioning mode. Please make sure that the
water outlet is closed with the rubber cap during operation.
The unit stands in the room to be cooled.
Connect the exhaust hose and the air outlet grid to the unit as displayed in the illustration. The hose
must be connected on the side with the warm air icon
. The warm extract air must be emitted
from the room via the exhaust hose. Make sure that no warm outside air can enter the room. For
effective cooling, we recommend our selection of various accessories which reduce or prevent entry
of warm air into the room.
Set the function to “COOLING“. Set the target temperature using the temperature control. The
target temperature can range between 17°C and 30°C (65°F and 90°F). The unit can only be used
in an ambient temperature of maximum 32°C (92°F).
AIR CONDITIONING MODE – OUT OF ROOM OPERATION
The unit is outside the room to be cooled, such as adjacent room, hallway
etc.
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; hose must be
connected to the side with the COOL icon
. If the unit is placed out or room during high humidity periods,
we recommend that a drainage hose for condensation water be connected to the bottom water outlet for
effective cooling and additional moisture removal.
If the unit is working in conditions of high humidity it may display an E4 error code. See troubleshooting.
OPERATING INSTRUCTIONS