Kenmore 300 Series, 300 Series Water System User Manual


 
14
Connect Valve and Salt Tank Drains
CONNECT THE VALVE DRAIN HOSE
Take a length of 3/8” inside diameter drain tubing and
attach one end to the drain fitting. See Fig. 16. Use a
tube clamp to hold it in place. Put the other end of the
tubing over a floor drain, into a laundry tub, standpipe,
or other suitable drain. Check your local codes.
Leave an air gap of about 1-1/ 2'' between the end of
the hose and the drain. This gap is needed so you
don’t get a backflow of sewer water into the softener.
Do not put the end of the hose into the drain or con-
nect without the air gap.
Place and support the hose so it does not kink or have
sharp bends. Secure the hose end so water pressure
does not cause the hose to “whip”. Tie or wire it in
place. Do not pinch the hose shut. The softener will
not work if this drain hose is pinched, plugged,
closed or restricted in any way. Direct drain flow
down into drain from drain line as flow could possibly
over shoot the drain cover.
Keep the hose lower than the drain fitting. In some
homes, to get to a drain you must raise the hose and
run it overhead. If you need an overhead drain, do not
raise the hose more than 8' above the floor. A copper
drain tube is best to use.
COPPER DRAIN TUBE: Local plumbing codes may
require the use a copper valve drain tube. A copper
tube is also best to use for an overhead drain. Use a
copper drain tube if the softener is installed outside, or
in the sunlight. Heat from the sun can soften, flatten
and close up some kinds of tubes.
To adapt a copper drain tube to the softener, buy a
compression fitting (1/4'' female pipe threads x 1/2''
O.D. tube) and tubing from your local hardware store.
CONNECT SALT TANK OVERFLOW TUBING
1. Locate the rubber grommet, tube adaptor and tube
clamp (see Fig. 16) that are in the parts bag.
2. Push the grommet into the hole in the salt tank wall
so half is inside and half is outside.
3. Push the bigger end of the tube adaptor into the
grommet.
4. Push one end of a length of 3/8'' I.D. tubing onto the
tube adaptor, using the tube clamp to hold it in
place.
5. Put the other end of the tubing over the floor drain.
IMPORTANT: Overflow water must run downward
through the tubing. Do not raise the tubing higher
than the grommet and tube adaptor. See Fig. 16.
IMPORTANT: Do not connect to the valve drain
hose you installed in step 1. Both drains must
have a separate hose or tube.
NOTE: Overflow drain tubing is available from
Sears. See parts list in back of manual.
Questions? Call The Kenmore Water Line 1-800-426-9345
Tube
Clamp
Drain
Fitting
Grommet
Tube
Adaptor
Tube
Clamp
1/4 NPT Threads
Barbs
1/2” Outside Diameter
Copper Tube
(Not furnished)
Comp Fitting. 1/4 NPT x
1/2 in. O.D. Tube
(Not furnished)
Clip
Cut Barbs from Drain
Fitting (Pull clip and
remove fitting from valve.)
1-1/2”
Air Gap
STANDPIPE
1-1/2” Air Gap
LAUNDRY TUB
FLOOR DRAIN
1-1/2”
Air Gap
Tie or Wire
Tubing in Place
Valve Drain Hose
To drain
point other
than floor
drain.
Support
tubing in
place as
needed.
Overflow Drain Tubing
NOTE: Overflow
drain tubing is avail-
able from Sears,
Item No. 42-3433
(20 ft).
FIG. 16