Lighting Instructions
Read and understand these directions thoroughly before
attempting to light or re-light the pilot. Make sure the view port
is not missing or damaged. (See Figure 32.) Make sure the
tank is completely filled with water before lighting the pilot.
Check the rating plate near the gas control valve/thermostat for
the correct gas. Do not use this water heater with any gas other
than the one listed on the rating plate. If you have any questions
or doubts, consult your gas supplier or gas utility company.
WARNING
Explosion Hazard
Replace view port if glass is missing
or damaged.
Failure to do so can result in death,
explosion or fire.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:
FLAMMABLE
If you do not follow these instructions exactly, a
fire or explosion may result causing property damage, personal
injury or loss of life.
BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES
A.
C.
D.
B.
BEFORE LIGHTING
smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
Do not use this appliance if any part has been under
water. Immediately contact a qualified installer or
service agency to replace a flooded water heater.
Do not attempt to repair the unit! It must be replaced!
LIGHTING INSTRUCTIONS
TOP KNOB
FIGURE 'A'
"OFF" POSITION
OFF
ON
PILOT
FIGURE 'B'
"PILOT" POSITION
OFF
ON
PILOT
FIGURE 'C'
"ON" POSITION
OFF
ON
PILOT
1.
2.1.
TO TURN OFF GAS TO APPLIANCE
Set the thermostat to lowest setting
(PILOT LIGHTING).
Push gas control knob down slightly and turn clock-
wise to 'OFF'. Do not force. SEE FIGURE 'A'.
FIGURE "D"
1.
10.
11.
12.
13.
2.
3.
5.
6.
7.
8.
9.
STOP!
Read the safety information
above on this label.
Set the thermostat to lowest setting(PILOT LIGHTING).
Turn thermostat dial fully clockwise until it stops.
Push the gas control knob down slightly and turn
clockwise to "OFF". SEE FIGURE 'A'.
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed down slightly. Do not force.
Wait ten (10) minutes to clear out any gas. If you
then smell gas, STOP! Follow "B" in the
safety information
above on this label. If
you don't smell gas,
go to next step.
This unit is equipped with a push button pilot ignitor,
on the gas control.
Continue to hold the gas control knob down for about
one (1) minute after the pilot is lit. Release the gas
control knob and it will pop back up. Pilot should
remain lit. If it goes out , repeat step (3) through (9). It
may take several minutes for air to clear the lines
before the pilot will light.
If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
If the pilot will not stay lit after several tries,
turn the gas control knob clockwise to 'OFF' and
call your service technician or gas supplier.
SEE FIGURE 'A'
At arm's length away, turn gas control knob
counterclockwise to 'ON'. SEE FIGURE 'C'.
Set thermostat to desired setting.
Remove the outer burner door located below
4.
the gas control.
which is used to light the pilot. Locate the ignitor
Turn gas control knob counterclockwise
to "PILOT". SEE FIGURE 'B'.
Once the pilot flame is established replace the
outer burner door.
THERMOCOUPLE
MAIN BURNER
PILOT
The pilot is located on the left side of the burner. It
can be located by looking through the glass view port
while pressing the piezo ignitor button several times.
Look for a spark at the pilot location, Figure "D".
Once the pilot has been found, push the gas knob
all the way down. Immediately press the pilot ignitor
button rapidly (4) to (5) times. If the pilot will not
light, repeat step (3) through (9).
This appliance has a pilot which is lit by a piezo-
electric spark gas ignition system. Do not open
the inner door of the appliance and try to light
the pilot by hand.
DANGER: Hotter water increases the risk of
scald injury. Consult the instruction
manual before changing temperature.
DO NOT USE THIS APPLIANCE IF THERE HAS
BEEN AN IGNITION OF VAPORS. Immediately
call a qualified service technician to inspect the
appliance. Water heaters subjected to a
flammable vapors ignition will show a
discoloration on the air intake grid and require
replacement of the entire water heater.
E.
PIL0T
THERMOSTAT
DIAL
GAS CONTROL
KNOB
GAS CONTROL
PIEZO
IGNITOR
120° MARK