Kenmore 153.331592 Water Heater User Manual


 
Lighting Instructions
Read and understand these directions thoroughly before
attempting to light or re-light the pilot. Make sure the view port
is not missing or damaged. (See Figure 33.) Make sure the
tank is completely filled with water before lighting the pilot.
Check the rating plate near the gas control valve/thermostat for
the correct gas. Do not use this water heater with any gas other
than the one listed on the rating plate. If you have any questions
or doubts, consult your gas supplier or gas utility company.
Explosion Hazard
Replace view port if glass is missing
or damaged.
Failure to do so can result in death,
explosion or fire.
BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES
A. T,hisappliance has.a .pi.lotwhich is litby a piezo-
etec[rlc spark gas ignluon ,sys[em. uo n_,.o_open
the inner aoor of tiSeappliance and try [o light
the pilot by hand.
B.BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.
elmmediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
°If you cannot reach your gas supplier, call the fire
department.
C.Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water, immediately contact a qualified installer or
service agency to replace a flooded water heater.
Do not attempt to repair the unit! It must be replaced!
Pl_
tGNITOR STATUS_"
LED.
GASCONTROL
_GAS CONTROL FIGUREIA' FIGURE'B' FIGURE'C' MAINBURNER
KNOB \
"_ .... _,to__ "PILOT
"OFF" POSITION "PILOT" POSITION "ON" POSITION
CONTROL KNOB FIGURE 'D'
1.
2.
3.
4.
5.
6.
7.
8.
STOP! Read the safety information
above on this label.
Turn gas control knob fully counterclockwise
to "OFF". SEE FIGURE'A'.
Remove the outer burner door located below
the gas control.
Wait five (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow "B" in the
above on this label. If
youdon'tsmellgas, go to next step.
This unit is equipped with a push button pilot ignitor,
which is used to light the pilot. Locate the ignitor
onthe gas control.
Turn gas control knob clockwise
Cto "PILOT". SEE FIGURE 'B'.
The pilotis locatedonthe left sideoftheburner. It
can be locatedbylookingthroughthe glassview port
while pressingthepiezoignitorbuttonseveraltimes.
Lookfora sparkat thepilotlocation,Figure'D'.
Oncethe pilothas beenfound, push thegas control
knoballthewayin(towardthewaterheater.)Immediately
10.
11.
press the piezo ignitor button rapidly (4) or(5) times.
Ifthe pilotwill notlight,repeatedsteps(2)through(8).
Continuetohold _e gas controlknob infor about
(30)seconds after the pilotis lit untilthe statusLE.D.
isflashing (oneflash everythree secondsis normal.)
Releasethegascontrolknobandthepilotshould
remain lit.If itgoes out,repeatsteps (2) through (8).
It may take several minutes forair to clear the lines
before the pilot will light.
If the pilot will not stay lit after several tries,
turn the gas control knob counterclockwise
to "OFF"andcall your service technician or gas
supplier. SEE FIGURE 'A'.
Once the pilot flame is established replace the
outer burner door.
At arm's length away, turn gas control
knob clockwise C to desired temperature setting.
SEE FIGURE 'C'.
DANGER: Hotter water increases the risk
of scald injury. Consult the instruction
manual before changing temperature.
1. Turn control/thermostat knob fully counterclockwise _ to "OFF".
SEE FIGURE 'A'.
22