5
PRODUCT SPECIFICATIONS
MAXIMUM FUSE
RECOVERY RATE MINIMUM OR CIRCUIT
MODEL IN GALLONS GALS.PER HOUR WIRE SIZE* BREAKER
NUMBER (LITERS) DIA. HEIGHT @90
0
F Rise 120 Volt 240 Volt (GAUGE) SIZE (AMPS)
153.316040 6 (22.7)
14.250” (362)
15.375” (391)
7.5 1650 ---- 12 20
153.316050 10 (37.8)
16” (406)
18.25” (464)
7.5 1650 ---- 12 20
153.316060 19 (71.9)
18” (457)
24.9” (632)
7.5 1650 ---- 12 20
153.316070 19.9 (75.3)
16” (406)
31.62” (803)
7.5 1650 ---- 12 20
153.316331 30 (113.6)
22” (559)
30” (762)
7.5 1650 ---- 12 20
153.326060 19 (71.9)
18” (457)
24.9” (632)
9.1 ---- 2000 14 15
153.326070 19.9 (75.3)
16” (406)
31.62” (803)
9.1 ---- 2000 14 15
153.326331 30 (113.6)
22” (559)
30” (762)
9.1 ---- 2000 14 15
* Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.
Some compact models have labeled optional plumbing connections see below.
MODEL
NUMBER
STANDARD
SIDE COLD INLET
STANDARD
SIDE HOT INLET
STANDARD
SIDE T&P
MODEL HAS OPTIONAL
TOP COLD INLET
MODEL HAS OPTIONAL
TOP HOT OUTLET OR T&P
153.316040 YES YES YES YES, PLUGGED YES, PLUGGED
153.316050
YES YES YES NO YES, PLUGGED
153.316060
YES YES YES YES, PLUGGED YES, PLUGGED
153.316070
YES YES YES YES, PLUGGED YES, PLUGGED
153.316331
YES YES YES NO NO
153.326060 YES YES YES YES, PLUGGED YES, PLUGGED
153.326070 YES YES YES YES, PLUGGED YES, PLUGGED
153.326331 YES YES YES NO NO
DIMENSIONS
IN INCHES (mm)
TANK
CAPACITY
ELEMENT
WATTAGE
HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF
A LICENSED TRADESMAN IN THE FIELD INVOLVED.
PLUMBING AND ELECTRICAL WORK ARE REQUIRED.
Examine the location to ensure the water heater complies with the
“Facts to Consider About the Location” section in this manual.
5. For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during
an earthquake. See instructions for correct installation
procedures. Instructions may be obtained from California
Office of the State Architect, 400 P Street, Sacramento,
CA 95814.
6. Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR
2.00: State Plumbing Code and 248-CMR 5.00.