Jotul Woodstove F 400 Stove User Manual


 
9
Stove Unprotected Surface Protected Surface Installation
Clearances Installation PER NFPA211 OR CAN/CSA -B365-M93
Side Rear Corner* Side Rear Corner*
Stove -no heatshield 19" A 25" B 18" C 11” D 7" E 8" F
single wall pipe 485mm 635mm 460mm 280mm 180mm 205mm
Stove -with rear heatshield 18" G 18" H 13" I 11” J 7” K 8" L
single wall pipe 460mm 460mm 330mm 280mm 180mm 205mm
Stove -no heatshields 16” 19” 13” 8” 7” 6”
double wall pipe 405mm 485mm 330mm 205mm 180mm 150mm
Stove -with rear heatshield 15" M 7" N 11" O 8" P 7" Q 6" R
with connector shield 380mm 180mm 280mm 205mm 180mm 150mm
Stove -rear heatshield 15" S 7" T 11" U 8" V 7" W 6" X
with double wall pipe 380mm 180mm 280mm 205mm 180mm 150mm
Connector Unprotected Surface Protected Surface
Clearances (Pipe) Vertical Installation Vertical Inatallation
per NFPA211 OR CAN/CSA-B365-M93
Single wall pipe 25" 12"
635mm 300mm
Single wall pipe 18” 7”
with rear heatshield 460mm 180mm
Single wall pipe 7" 7"
with connector shields 180mm 180mm
Double wall pipe 7" 7"
180mm 180mm
Connector Unprotected Surface Protected Surface
Clearances (Pipe) Horizontal Installation Horizontal Installation
per NFPA211 OR CAN/CSA-B365-M93
Single wall connector 18" 460mm 7" 180mm
Double wall Pipe 6" 150mm 6" 150mm
Mantel and Trim Stove to 1" thick or less, side trim 13" 300mm
Clearances Stove to 1" thick or less, top trim 23" 585mm
Stove to mantel- maximum mantel depth 12" 25" 635mm
Jøtul F 400 Woodstove Clearances
USA/Canada