Jotul Woodstove F 400 Stove User Manual


 
34
ENGLISH
inlet of the stove. From there a flexible hose is conducted
out of the house. The installation instruction for this is
enclosed with the installation unit.
Assembly prior to installation
Jøtul F 400 is sold in many countries with varying demands
on fireplaces. This means that the buyer of the fireplace in
Europe must make a few small changes before installing
the product.
1. Just inside the door is an inspection cover fastened by 2
screws on the outer edge. The inspection cover is to be
removed and replaced by a corresponding part stored
in the ash box. It is marked:
Europa. Europa.
Europa. Europa.
Europa. Remove the safety
screw (fig.6) located in the centre and mount it on the
new inspection cover marked Europa.
2. The top plate is fastened by means of 2 transport
screws. These must be removed due to the regulation
regarding free access for sweeping smoke pipes. This
is done by first unscrewing the smoke outlet so that
the 2 transport screws situated on the inside of the
product between the side panels and the top plate are
within reach.
NB! Be aware of that the top plate is laying loose on the
top of the product, and shall not be fastened.
Insert the ash lip, which is stored inside the burn chamber,
into the grooves under the door.
The burn chamber also contains a heat shield, which is to
be mounted under the ash house. Unfold the heat shield
(see fig. 2A) and fasten it with the two screws attached to
the ash house (2B).
Screw the door handle knobs to the front door handle and
the ash door handle. (Fig. 3 B+C and fig. 7)
Control of functions (fig. 3)
When the product is set up,
always
check the control
functions. These shall move easily and function
satisfactorily.
Draught vent (A)
Left position = closed.
Right position = fully open.
Doorhandle (B)
Towards the left= open.
Towards the right=closed.
Ash door (C)
Open the door by turning the door handle counter-clockwise
one half rotation. Use a glove or similar and pull out the
tray.
Note! Only remove the ashes when the stove is cold.
Mounting of flue pipe
It is advisable to carry out a test assembly prior to making
a hole in the chimney. See fig. 1
for measures to wall made
of inflammable materials. The stove is installed with a 150
mm diameter flue pipe. This must be an approved thickness.
Jøtul F 400 is factory-assembled for a top flue outlet. If a
rear flue outlet is preferred, loosen the two screws on the
sides and rotate the connecting pipe 180
0
. Then fasten the
screws securely.
The 150 mm diameter flue pipe is placed directly with
the narrowest outer end onto the product flue outlet.
There is a screw on each side of the product flue outlet
(fig. 4-A). These will be used to fasten the flue pipe.
Indicate with marks where the screws hit the flue pipe
when the pipe is at the bottom of the flue outlet and
drill a 5,5 mm hole in the flue pipe for the screw.
Use a gasket rope to seal the space between the flue
pipe and the product flue outlet.
Fasten the flue pipe with the screws.
Note! It is important that the joints are completely sealed.
Air leakage etc. may lead to malfunction.
Connection to chimney
Drill a hole for the flue pipe. Distance from stove to firewall/
chimney should be as shown in fig. 1. Always use a chimney
collar when connecting to chimney. Use the supplier’s
recommended chimney collar when connecting to an
element chimney. Follow the supplier’s assembly and usage
instructions closely with regard to mortar/furnace cement
before starting to use the fireplace.
Ensure that the flue pipe never slopes down towards the
chimney. It should at least be horizontal, preferably have
an incline of a few millimeters.
Note! A correct and sealed connection is very important
for the proper functioning of the product.
Be alert to the fact that it is particularly important that
connections have a certain flexibility. This is to prevent
setting of the house from leading to fissuration.