Jotul F 500 Stove User Manual


 
UNPROTECTED SURFACE PROTECTED SURFACE NFPA 211
STOVE CLEARANCES PARALLEL INSTALLATION PARALLEL INSTALLATION
SIDE REAR CORNER* SIDE REAR CORNER*
Stove-no heatshield 14" A 18" B 13" C 6" D 12" E 9" F
Single wall pipe 355mm 460mm 330mm 150mm 300mm 230mm
Stove-with rear heatshield 14"
G 10" H 9" I 6" J 10 K 9" L
Single wall pipe 355mm 255mm 230mm 150mm 255mm 230mm
Stove-with rear heatshield 14"
M 6" N 9" O 6" P 6" Q 6" R
with connector shield 355mm 150mm 230mm 150mm 150mm 150mm
Stove-rear heatshield 14"
S 6" T 9" U 6" V 6" W 6" X
with double wall pipe 355mm 150mm 230mm 150mm 150mm 150mm
CONNECTOR UNPROTECTED SURFACE PROTECTED SURFACE NFPA 211
CLEARANCES (pipe) VERTICAL INSTALLATION VERTICAL INATALLATION
Single wall 18" 12"
with no heatshields 460mm 300mm
Single wall 6" 6"
with connector shields 150mm 150mm
Double wall pipe 6" 6"
150mm 150mm
UNPROTECTED SURFACE PROTECTED SURFACE NFPA 211
HORIZONTAL INSTALLATION HORIZONTAL INSTALLATION
Single wall connector 18" 460mm 12" 300mm
Double wall Pipe 6" 150mm 6" 150mm
MANTEL AND TRIM Stove to 1" thick or less, side trim 12" 300mm
CLEARANCES
Stove to 1" thick or less, top trim 16" 410mm
Stove to mantel- maximum mantel depth 12" 30" 765mm
* ATTENTION: STOVE AND PIPE CLEARANCES MUST BOTH BE TAKEN INTO CONSIDERATION.
THE GREATER CLEARANCE DICTATES THE STOVES POSITION.
* USE OF THE LEFT SIDE LOAD DOOR IS PROHIBITED IN ALCOVE AND CORNER
INSTALLATIONS.
12
OSLO F500 WOODSTOVE CLEARANCES