Hunter Fan Evaporative Humidifier Humidifier User Manual


 
41713-01 07/19/2004 7 ©2004 HUNTER FAN CO.
ENGLISH
Using Your Digital Humidistat
Setting the Desired Humidity
NOTE: After unplugging the humidifi er to
move the humidifi er, to refi ll the water tank
or to clean the humidifi er, you must reset the
digital humidistat.
Refer to Figure 6.
1. Use the power/speed control knob
to turn the humidifi er ‘ON’ by selecting a
speed setting.
NOTE: A speed setting must be chosen
before the humidistat will operate the
humidifi er.
2. In normal mode use the humidistat
control buttons to set the desired humidity
level. The settings range from 30% to 80%
in 5% increments.
3. When the humidity exceeds the level
you have set, the humidistat light will go
off. The humidifi er will not output humidity
while the humidity in the room is at the se-
lected humidity level. The humidistat light
will stay off until the humidity changes.
When the humidity in the room drops be-
low the selected level, the humidifi er will
cycle on again and the humidistat light will
come on.
Setting the Span
Refer to Figure 7.
Your humidistat is set at the factory to cycle at
setting 2. If you fi nd your system cycling too
fast or too slow, then the Span can be adjusted
to modify the cycle time.
4. Press and hold both humidistat con-
trol buttons for two seconds to enter span
setting mode.
5. In span mode, use the humidistat
control buttons to adjust the span. Raise
the span to 3 to increase the cycle time and
allow your system to run longer. Lower the
span to 1 to decrease the cycle time and
allow your system to run shorter.
6. The humidistat display will return
to normal mode after keys are idle for 5
seconds.
Humidistat
Light
Humidistat Control
Buttons
Figure 6
Figure 7
Humidistat Control
Buttons
41713_booklet.indd 7 7/19/04, 7:22:38 PM