Hunter Fan 44668 Thermostat User Manual


 
6
TEMPERATURE RANGE
6
Your thermostat can be programmed between 45°F
and 95°F (7°C and 35°C). However, it will display room
temperatures from 15°F to 99°F (-9°C and 37°C). “HI” will
be displayed if the temperature is higher than 99°F (37°C),
and “LO” will be displayed if the temperature is lower than
15°F (-9°C).
AUTO RECOVERY
7
Your thermostat is set from the factory to gradually
recover the room temperature from an energy saving
program to your comfort program. Therefore, the ther-
mostat may turn your system on several minutes prior to
your programmed time. This operation is normal, but can
be turned o. Refer to the Options Menu information on
pages 16.
OPERATION
8
NOTE: The INDIGLO
®
Night-Light will not function when
the battery power is low.
BATTERY WARNING
9
Two fresh AA alkaline batteries should provide well
over one year of service. However, when the batteries
become drained, the Low Battery Indicator will ash on the
display. when this message occurs, install new alkaline bat-
teries. You have appoximately one minute to change the
batteies and keep the thermostat’s clock and program set-
tings. Once the batteries have become too low to ensure
proper operation, your system will be turned o, and the
display will be cleared except for the ashing Low Battery
Indicator on the LCD display.
CAUTION: When only the battery Icon ashes on the
display, the display, the thermostat is shut down and your
system will no longer operate. In this condition, there is no