Hunter’s Auto Recovery feature meets the ENERGY STAR
®
guidelines for energy eciency by allowing the heating or
cooling system to recover gradually from an energy-saving
setpoint temperature to a comfort setpoint temperature.
Auto Recovery calculates how early to turn your system
back On, so that the room temperature is already comfort-
able by the start of the comfort temperature program pe-
riod. Auto Recovery works in both Heat and Cool modes.
For example, in Heat mode, you could have the following
programs:
Program #4 (Overnight) Program #1 (Morning)
Set Temp = 60°F Set Temp = 68°F
Time = 10PM Time = 6AM
The room temperature fell to 60°F overnight. Rather than
having the thermostat turning on at 6AM, Auto Recovery
would note the temperature dierence between 60°F and
68°F and turn the Heat on approximately 30 minutes early.
Therefore, the room temperature at 6AM would be about
68°F instead of 60°F.
When the thermostat is in Auto Recovery mode, the
display will alternate “RECOVERY” with the day, and the
program indicator will ash.
Auto Recovery
Details of Auto Recovery Operation:
Auto Recovery can be disabled by selecting “NO” in the Op-
tion Menu. Refer to page 17.
Auto Recovery will not operate if Permanent hold, Vaca-
tion hold Temporary hold or Home Today is in operation.
Auto Recovery can be canceled manually if RET CLEAR
is pressed during the recovery process. If a recovery
process is canceled manually then the recovery process
will not start again until the next program period starts
(an exception is that if time or program is changed then
the thermostat will check Auto Recovery conditions im-
mediately).
Auto Recovery will be canceled if HOME TODAY or HOLD
is pressed during the recovery process. The thermostat
will enter Home Today, Permanent Hold, or Vacation
Hold.