Hunter Fan 30130 Air Cleaner User Manual


 
15 41451-01
Programming
To set or change the programs:
1. Press the PROGRAM key. Program 1 for weekdays will
be shown with the hour position flashing to denote that
you should set that value now.
2. Use the UP/DOWN keys to adjust the hour setting. Once
set, press the PROGRAM key again.
3. Now, the minute position will be flashing. Use the UP/
DOWN keys to adjust the minute setting in 10 minute
increments. Press PROGRAM to accept the value.
4. Finally, the blower speed will be flashing. Use the UP/
DOWN keys to adjust the blower speed setting from 0 to
3. Zero indicates that the blower is turned off, a setting of
1 is low, 2 is medium, and 3 represents a blower speed of
high. Press PROGRAM to accept the blower speed setting.
This completes the first program for weekdays.
5. The display will advance to the second program for
weekdays with the hour position flashing. Follow steps
2 to 4 to set the second program. After setting each pro-
gram, the display will advance to the next program num-
ber. After going through all four weekday programs, the
unit will advance through each of the four weekend pro-
grams. The adjustment procedure (steps 2 to 4) is the
same for each program.
Fig. 23
Fig. 24
Fig. 25
PROGRAM
PROGRAM
PROGRAM
PROGRAM
NOTES:
•For fast advance of the values, press and hold the UP/DOWN keys for 2 seconds. The
values for program time or blower speed will advance quickly.
•To exit programming mode and return to normal operating mode, either wait 15
seconds without any key presses or press DISPLAY to immediately return to normal
operating mode.
Once entered, the programs are active and stored in the unit’s memory. You can
unplug and move the air purifier and still retain the programs.
41451-01_Rev 8-6-04.pmd 8/5/04, 5:05 PM15