6, With curved ends down, slide end
plates (C) of brush roll into slots (E)
on tool,
7, Replace belt guard (B) making
sure not to pinch brush bristles in
guard, Turn agitator, to make sure it
rotates freely,
Replace and tighten screws,
8, To replace bottom plate (A), insert
the four tabs on edge of bottom
plate into slots on front of tool,
Pivot bottom plate down and snap
closed,
Powered hand tool
Belt replacement
Inspect the belt
The powered hand tool belt is
designed to last a long time and is
not normally replaced, However, if
the belt is cracked, gouged or bro-
ken, it should be replaced,
1. Remove tool from hose. The
belt can be seen through the top of
the nozzle or by removing the bot-
tom plate and belt guard (Figs, 3-24
and 3-25),
Replace belt
When replacing belt, ask for
HOOVER part No. 38528-037.
2, Grasp turbine (A) and pull firmly
to remove,
3, Remove belt from turbine pulley
(B), Replace with new belt,
4, With flat sides of turbine retainers
(C) pointing down, slide retainers
into grooves (D) in tool housing and
snap into place,
5, Replace brush roll, belt guard,
and bottom plate as described in
Figs, 3-26 through 3-29,