Honeywell VISTA-15P Home Security System User Manual


 
*161
Pager 1 Characters
Enter up to 16 characters.
Up to 16 optional characters may be sent as a prefix to
the 7-digit system status code sent to Pager #1 (if used).
Phone number in field *160 must have been entered. If
fewer than 16 characters, exit by pressing [] and next
field number. To clear entries: press 161.
The 16 characters may be composed of the following:
PIN number, Subscriber account number,
(enter # + 11 to send ), # (enter # + 12 to send #),
Pause (enter # + 13 to allow a 2-second pause),
special character(s) the user may decide to transmit
† Some paging systems require pause(s) before the prefix.
The Pager format for the 7-digit status code is defined
as follows: XXX-YYYY where:
XXX = 3-digit event code: 911 = Alarm, 811 =
Trouble, 101 = Opening (disarm), 102 =
Closing (arm AWAY)
YYYY = 4-digit user or zone number (depending on
type of event). The first digit indicates partition (0 =
system, 1 = part 1, 2 = part 2, 3 = common), followed
by the 3-digit user or zone number.
Display Example 1. 9111004 Indicates an alarm
(911) caused by a fault in zone 4 (0004) in part. 1.
Display Example 2. 1022005 Indicates the system
is reporting a closing–system arming (102) by User 5
(0005) in partition 2.
*162
Pager 1 Report Options
0 = No reports sent; 1 = Open/close for all users enabled
to page; 4 = All alarms and troubles
5 = All alarms, troubles, and open/close for all users
enabled to page
12 = Alarms and troubles for zones entered in zone list 9
13 = Alarms and troubles for zones listed in zone list 9
and open/close for all users enabled to page
Enter the types of reports to be sent to Pager 1 for each
partition.
Reports to pager only when arming (close)/disarming (open)
from a keypad using a security code; auto-arming/disarming,
arming with assigned button, and keyswitch arming do not
send pager messages.
*163
Pager 2 Phone No.
up to 20 digits
If entering fewer than 20 digits, exit by pressing [] +
next field number. To clear entries, press 163.
*164
Pager 2 Characters
up to 16 characters
See field 161 for explanation of entries. If fewer than
16 characters, exit by pressing [] and next field
number. To clear entries, press 164.
*165
Pager 2 Report Options
See pager 1 reports, field *162 for entries, except use
zone list 10
*166
Pager 3 Phone No.
VISTA-20P. Enter up to 20 digits
If entering fewer than 20 digits, exit by pressing [] +
next field number. To clear entries, press 166.
*167
Pager 3 Characters
VISTA-20P. Enter up to 16 characters
See field 161 for explanation of entries. If fewer than
16 characters, exit by pressing [] and next field
number. To clear entries, press 167.
*168
Pager 3 Report Options
VISTA-20P. See pager 1 reports, field *162, except use
zone list 11
*169
Pager 4 Phone No.
VISTA-20P. Enter up to 20 digits
If entering fewer than 20 digits, exit by pressing [] +
next field number. To clear entries, press 169.
*170
Pager 4 Characters
VISTA-20P. Enter up to 16 characters
See field 161 for explanation of entries. If fewer than
16 characters, exit by pressing [] and next field
number. To clear entries, press 170.
*171
Pager 4 Report Options
VISTA-20P. See pager 1 reports, field *162, except use
zone list 12
*172
Pager Delay Option for Alarms
0 = none; 2 = 2 minutes; 1 = 1 minute; 3 = 3 minutes
This field determines the delay of alarm reports to the
pager. This gives the Central Station enough time to
verify the alarm report that it received, before the
dialer attempts to dial the pager.
This delay is for ALL pagers in the system
Miscellaneous System Fields
*174
Clean Me Option
0 = disable; 1 = enable
This is a maintenance feature for ESL 2-wire smoke
detectors on Zone 1. If used, this option limits the
number of smoke detectors to a maximum of 10, rather
than 16. To enable the “clean me” feature, a time
response setting of “3” (1.2 seconds) must be entered in
56 Zone Programming for zone 1.
*177
Device Duration 1, 2
0 = 15 secs 4 = 90 secs 8 = 4 min #+12 = 8 min
1 = 30 secs 5 = 2 min 9 = 5 min #+13 = 10 min
2 = 45 secs 6 = 2-1/2 min #+10 = 6 min #+14 = 12 min
3 = 60 secs 7 = 3 min #+11 = 7 min #+15 = 15 min
These entries set the duration for output action options
5 (duration 1) and 6 (duration 2) programmed in 80
Output Function Programming.
*181
50/60 Hz AC Operation
0 = 60 Hz; 1 = 50 Hz
Select the type of AC power applied to the control
(option is used for Real-Time Clock synchronization)
Installation and Setup Guide
4-8