Honeywell VISTA-15P Home Security System User Manual


 
Interactive Mode Programming (
56, *57,
58,
79,
80,
81,
82)
Entering Interactive Mode
Press [
] + [Interactive Mode No.] (for example,
56) while in Program Mode. The Alpha
display keypad will display the first of a series of prompts.
After making the appropriate entry, press the [] key to accept the entry and continue to
the next prompt.
Loading Factory Defaults/Initializing for Download
To Load Default Entries
Press 97 while in Program Mode. This resets all data fields to the default values shown
on the Program Form. Use
97 only if you wish to return to the original factory-
programmed defaults.
To Initialize Download ID
Press 96 while in Program Mode. This initializes the system for downloading and resets
all the subscriber account numbers and CSID.
Do not press
97 to load defaults if any programming has been done previously—data
already programmed into the system will be changed!
Exiting the Programming Mode
Prevent installer code
reentry
Press 98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if
98 was used to exit,
you must first power the system down. Then power up again, and press [] and [#] at the
same time, within 50 seconds of powering up.
See field *88 for other Program mode lockout options.
Allow installer code
reentry
Press 99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [] and [#] at the same time, within 50
seconds of power-up.
Zone Type Definitions
Zone types define the way in which the system responds to faults in each zone.
Zone Type Description
Type 00
Zone Not Used
Program a zone with this zone type if the zone is not used.
Type 01
Entry/Exit
Burglary #1
Assign to zones that are used for primary entry and exit.
Provides entry delay when zone is faulted if control is armed in the Away, Stay, or Night-Stay
modes.
No entry delay provided when the panel is armed in the Instant/Maximum mode.
Entry delay #1 is programmable for each partition (field *35).
Exit delay begins whenever the control is armed, regardless of the arming mode selected, and
is programmable (field
34).
Type 02
Entry/Exit
Burglary #2
Assign to zones that are used for entry and exit and require more time than the primary
entry/exit point.
Provides a secondary entry delay, in same manner as entry delay #1.
Entry delay #2 is programmable for each partition (field *36).
Exit delay is same as described for Type 01.
Type 03
Perimeter
Burglary
Assign to all sensors or contacts on exterior doors and windows.
Provides an instant alarm if the zone is faulted when the panel is armed in the Away, Stay,
Night-Stay, Instant or Maximum modes.
Type 04
Interior Follower
Assign to a zone covering an area such as a foyer, lobby, or hallway through which one must
pass upon entry (to and from the keypad).
Provides a delayed alarm (using the programmed entry 1 time) if the entry/exit zone is faulted
first. Otherwise this zone type gives an instant alarm.
Active when the panel is armed in the Away mode.
Bypassed automatically when the panel is armed in the Stay or Instant modes;
if armed in Night-Stay mode, zones assigned to zone list 05 (night-stay zone list) are not
bypassed when system armed in Night-Stay mode.
Installation and Setup Guide
3-2