Honeywell TH8110U Thermostat User Manual


 
TH8110U TOUCH SCREEN PROGRAMMABLE THERMOSTATS
9 69-1700
Table 5. Regional Settings Menu.
Select
Installer
Setup
Number
Factory Setting Other Choices
CommentsOption Description Options Description
Changeover 0300 0 Manual changeover 1 1—auto
changeover
Deadband 0310 3 Heating and cooling
setpoints can be set
no closer than 3
°
F
(1.5
°
C)
2 thru 9 Heating and
cooling setpoints
can be set no
closer than
chosen value:
2—2
°
F (1
°
C )
3—3
°
F (2
°
C )
4—4
°
F (2.5
°
C )
5—5
°
F (3
°
C )
6—6
°
F (3.5
°
C )
7—7
°
F (4
°
C )
8—8
°
F (4.5
°
C )
9—9
°
F (5
°
C)
Shown only if
automatic
changeover is
selected.
Temperature
Indication
Scale
0320 0 Temperature is
displayed in
°
F.
1 Temperature is
displayed in
°
C.
Daylight
Savings
0330 1 Daylight savings
enabled (United
States).
0 0—daylight savings
is disabled.
Set to 0 in areas that
do not follow
daylight savings.
Remote
Temperature
Sensor
(Outdoor or
Indoor)
0340 0 No remote
temperature sensor
1,3 1—outdoor
temperature sensor
for display only.
3—indoor
temperature sensor
Defaults and
Options depend on
System Type
selected. Indoor
Temperature Sensor
uses an averaging
network and does
not include on-board
sensor.