Powering the Thermostat
There are two different ways to power the thermostat:
Batteries (three AAA alkaline).
24 Vac Common wire.
Wiring 24 Vac Common
Wire the common side of the transformer to the C screw
of the thermostat wallplate. When installing in a single
transformer system, keep jumper wire between the R
and Rc screws. When installed in a two-transformer
system, use the common from the cooling transformer to
connect to C screw and remove the jumper wire between
the R and Rc screws.
Inserting Batteries (Optional)
If not using a 24 Vac Common to power the thermostat,
install three AAA alkaline batteries (included) in the back
of the thermostat. Make sure the positive and negative
terminals are oriented correctly, as marked on the device.
See Fig.12.
M19899
OUTDOOR/INDOOR
TEMPERATURE
SENSOR
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
FACTORY INSTALLED JUMPER.
OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE
ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE
FROM THE THERMOSTAT CABLE.
1
3
2
3
Y2
RC
S1
R
S2
W
W2
Y
G
C
2
CONVENTIONAL
R
TR
C
1
TR
W BR
SERIES 20
MOTOR OR
VALVE
M19900
OUTDOOR/INDOOR
TEMPERATURE
SENSOR
FAN
RELAY
R
C
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
FACTORY INSTALLED JUMPER.
OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE
ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE
FROM THE THERMOSTAT CABLE.
1
1
3
2
3
OPTIONAL
24 VAC
COMMON
CONNECTION
Y2
RC
S1
R
S2
W
W2
Y
G
C
2
CONVENTIONAL
COMPRESSOR
CONTACTOR
1
2
3
4
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
FACTORY INSTALLED JUMPER.
"O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP.
OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE ON SELECT MODELS.
WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE.
Y2
L
E
AUX
S1
S2
RC
R
O/B
Y
G
C
M19903
R
C
1
OPTIONAL
24 VAC
COMMON
CONNECTION
2
OUTDOOR/INDOOR
TEMPERATURE
SENSOR
FAN RELAY
4
CHANGEOVER
VALVE
3
HEAT PUMP
COMPRESSOR