Honeywell T8611G Thermostat User Manual


 
T8611G CHRONOTHERM
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
69-1406—1 6
IMPORTANT
Review the settings to confirm that they match
the system. Press Run Program to exit the
Installer Setup. The thermostat has saved the
Installer Setup changes and initiated a reset in
order to operate using the new settings. Be sure
to set the current day and time immediately.
Temperature
display
adjustment.
37 0 No difference in
displayed
temperature and
actual room
temperature.
-3 thru 3 1—Display adjusts to 1°F
higher than actual room
temperature.
2—Display adjusts to 2°F
higher than actual room
temperature.
3—Display adjusts to 3°F
higher than actual room
temperature.
-1—Display adjusts to 1°F
lower than actual room
temperature.
-2—Display adjusts to 2°F
lower than actual room
temperature.
-3—Display adjusts to 3°F
lower than actual room
temperature.
Furnace Air
Filter Timer.
43 0 Off 1, 2, 3, 4 1 – 10 days
2 – 30 days
3 – 60 days
4 – 120 days
(Times counted when heat,
cool or fan is running.)
Humidifier Pad
Monitor.
44 0 Off 1, 2, 3 1 – 90 days
2 – 180 days
3 – 365 days
(Times counted by calendar
days in heat mode.)
Ultraviolet (UV)
Air Treatment
System Lamp
Monitor.
45 0 Off 1 1 – 365 days
(Times counted by calendar
days in any mode.)
Table 3. Thermostat Installer Setup Options. (Continued)
Select
Installer Setup
Number (Press
Time key to
change)
Factory Setting
Other Choices
(Press or key to change)
Actual
SettingDisplay Description Display Description