Honeywell T8611G Thermostat User Manual


 
T8611G CHRONOTHERM
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
69-1406—1 4
Temperature Settings
Refer to Table 2 for the default program. If the daytime
energy savings period is not used, press the period key
(Leave or Return) until the time is blank. The fan setting
feature is available on select thermostat models. See
Owner’s Guide, form number 69-0940, for complete
instructions on changing the program.
Table 2. Default Program Settings.
INSTALLER SETUP
NOTE: For most applications, the thermostat factory-
settings will not need to be changed. Review
the factory settings in Table 2 and if no changes
are necessary, go to the Installer System Test
section.
The Installer Setup is used to customize the thermostat
to specific systems. Some of the options include
temperature display, changeover and outdoor
temperature display. Installer Setup numbers are listed in
Table 3. The table includes all the configuration options
and the factory-settings for the T8611.
A combination of key presses is required to use the
Installer Setup feature:
— To enter the installer setup, press and hold the
information i key with the increase and
decrease keys until the first number is displayed.
All display segments appear for approximately three
seconds before the number is displayed. See Fig. 9
and 10.
— To advance to the next Installer Setup, press the
Time key.
— To change a setting, use the increase or decrease
key.
— To scroll the Installer Setup numbers backward, press
the Time key.
— To exit the Installer Setup, press Run Program.
Fig. 9. Display of all LCD segments.
Fig. 10. Display of Installer Setup
number and setting.
IMPORTANT
Only configurable numbers are shown on the
device. Example: If thermostat does not have a
system key, Installer Setup Number 12 will not
be displayed. Review Table 3 factory-settings
and mark any desired changes in the Actual
Setting column. When Installer Setup is com-
plete, review the settings to confirm that they
match the system.
Period Time
Heat
Setpoint
Cool
Setpoint
Fan
Setting
Wake 6:45 AM 20°C
(68°F)
25°C
(77°F)
Auto
Leave 8:45 AM 4.5°C
(40°F)
37°C
(99°F)
Auto
Return 5:00 PM 20°C
(68°F)
25°C
(77°F)
Auto
Sleep 10:00 PM 4.5°C
(40°F)
37°C
(99°F)
Auto
M14559
Aux Ht
Set Day/TimeSet Program
Mon
Wake Leave Return Sleep
Ou
t
door
Room
Filter
Wait
F
Fan
Em H
eat
On
A
u
t
o
O
f
f
C
oo
l
A
u
t
o
AM
PM
Hold for
Heat
Cool
Repl Batt
Recovery
DST
TueWedThu Fri Sat Sun
Days
Temporary Setting
Em Ht
M14618
INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2 OF TABLE 3)
FACTORY SETTING OR OTHER
CHOICE DISPLAY (COLUMN 3
OR 5 OF TABLE 3)
Table 3. Thermostat Installer Setup Options.
Select
Installer Setup
Number (Press
Time key to
change)
Factory Setting
Other Choices
(Press or key to change)
Actual
SettingDisplay Description Display Description
Not Used. 1 thru 4
Heating cycle
rate.
5 6 Stage 2 1, 6 or 9 1—1 cph
6—6 cph used for last stage
of heat pump systems
9—9 cph used for electric
heat
6 (Not used)
7 6 Emergency heat 3, 6 or 9
Not Used. 8 thru 11
System setting
adjustment
12 1 Manual
changeover
0 or 2 0—Auto changeover
2—Fixed auto changeover