Honeywell LYNXR24 Home Security System User Manual


 
11
6<67(029(59,(:
$ERXWWKH'LVSOD\DQG,QGLFDWRUV
'LVSOD\'HILQLWLRQV
ALARM
AWAY
INSTANT
STAY
FIRE
REC MESSAGE
BYPASS
FAULT
CHIME TEST
LOW BAT AC
ALARM: Appears when the system is armed and an intrusion has been detected (also appears during a
fire alarm or audible emergency alarm). Accompanied by the protection zone that is in alarm.
AWAY: All burglary zones, interior and perimeter, are armed.
INSTANT: Entry delay is turned off.
STAY: Perimeter burglary zones, such as protected windows and doors, are armed.
FIRE: Appears when a fire alarm or fire fault is present. Accompanied by a display of the zone that is
in alarm.
LOW BAT: Low battery condition in a wireless sensor (if zone number is displayed) or low system battery (if
no zone number is displayed). If 00 is displayed, a wireless keypad (5827) has a low battery
condition.
AC: Appears when AC power is present. If not displayed, the system is operating on backup battery
power.
CHIME: Appears when the Chime feature is activated.
TEST: Appears when the system is in Test mode.
REC: Appears when the system is in Recording mode.
MESSAGE: Appears when a message has been recorded and has not yet been played back.
BYPASS: Appears when one or more burglary protection zones have been bypassed.
FAULT: Appears at any time a malfunction is discovered in the system; or any time an open is detected
in a fire zone; or when a fault in a day/night burglary zone is discovered during a disarmed
period. Accompanied by a display of the zone number in trouble.
PH: Appears in place of the clock when the speaker phone mode is active.
/('0HDQLQJV
ARMED LED: ON = System armed
(Red) OFF = System disarmed
Blinking = System armed, but a fault exists
READY LED: ON = System disarmed, ready to arm
(Green) OFF = System armed
Blinking = System disarmed, not ready to arm (a fault exists)