Honeywell HE360B Humidifier User Manual


 
HE360A,B POWERED FLOW-THROUGH HUMIDIFIER
9 69-1176—04
2. Make sure the humidifier housing is level, then position it in the opening so the
plastic tabs are in place on the lower sheet metal edge of the opening. Use pli-
ers, as necessary, to flatten cut edges. See Fig. 4.
3. Push in securing clips until completely seated.
4. Drill holes and install the three sheet metal screws on the top of the humidifier
housing. Secure the housing with the three remaining screws.
Fig. 4. Installing humidifier on duct.
5. Reinstall the humidifier pad assembly in the humidifier housing.
IMPORTANT
Be sure to reconnect the water feed tube and ensure that the tube is not
pinched or kinked.
6. Hinge the cover in place and secure with the thumbscrew located at the bottom
of the cover.
DUCT
LEVEL
SHEET METAL
SCREWS (4)
PLASTIC
TABS (2)
DRAIN TUBING
M20204
OPENING
TO AIR DUCT
69-1176_A.fm Page 9 Monday, December 7, 2009 9:11 AM