HE360A,B POWERED FLOW-THROUGH HUMIDIFIER
69-1176—04 6
INSTALLATION
Preparing for the Installation
Be sure to identify all the required (Table 1) accessories (included) and make sure the
appropriate tools are available before beginning the installation.
Installing the Humidifier
WARNING
Hazardous Voltage
Can cause personal injury or equipment damage.
Do not cut or drill into any air conditioning or electrical accessory.
CAUTION
Sharp Edges Installation Hazard.
Can cause personal injury.
Wear gloves and safety glasses.
1. Turn off power to the air handing system at the circuit breaker.
2. Draw a level line on the plenum in the location
chosen for the humidifier. (Leveling assures optimal humidifier performance.)
3. Locate the template (form number 69-1651 included in the box).
4. Tape the template in position and trace around the template.
5. Remove the template and carefully cut the rectangular opening.
6. Disassemble the humidifier; remove the cover and take out the humidifier pad
assembly. See Fig. 1.
Fig. 1. Disassembling humidifier.
M12809
COVER
ASSEMBLY
HUMIDIFIER
PAD ASSEMBLY
FEED TUBE NOZZLE
WATER
DISTRIBUTION TRAY
HUMIDIFIER
HOUSING
THUMB
SCREW
69-1176_A.fm Page 6 Monday, December 7, 2009 9:11 AM