Honeywell HE360B Humidifier User Manual


 
HE360A,B POWERED FLOW-THROUGH HUMIDIFIER
13 69-1176—04
Fig. 8. Adapting sail switch to air flow direction or mounting position.
Vertical downward air flow: Leave the spring in place that is attached to the
bracket marked Down. Remove the spring that is attached to the bracket marked
Up.
Vertical upward air flow: Leave the spring in place that is attached to the bracket
marked Up. Remove the spring that is attached to the bracket marked Down.
Horizontal air flow: Remove both springs.
1. Mount the template (provided with the sail switch) at the desired location.
NOTE: Be sure the arrow (indicating air flow) points in the correct direction.
a. For horizontal mounting, level the long dimension shown on the template.
b. For vertical mounting, plumb the long dimension.
2. Cut the hole (indicated on the template) in the ductwork.
3. Center punch the screw holes indicated and drill out with a 1/8 in. (13 mm) drill.
4. Attach the sail to the switch as shown in Fig 9.
UP
M3014