Honeywell HCM-6009 Humidifier User Manual


 
8
POWER
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET
HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.
• With the power OFF, plug the filled humidifier into a polarized 120V
outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it
will only fit one way.
STEP 1: POWER
• Press the Power button to start the humidifier. Your humidifier will
automatically start on High power, Continuous Mode. The display will
be illuminated and will reflect the current room humidity (Fig. 10).
• To turn your humidifier OFF simply press the Power button again.
STEP 2: OUTPUT / FAN SPEED CONTROL
Your unit has three output levels/fan speeds:
HIGH: For fast humidifying
MED: For everyday moisture control
LOW: For minimum operation (ideal for nighttime use)
• To change your fan speed press the fan speed button ( ) up or
down (Fig. 11).
• Once you have selected your desired speed the display will go back
to showing the current room humidity after 3 seconds.
NOTE: If you wish to change or check your output/speed setting simply
press the fan speed button ( ) once and it will show you your setting.
If you would like to change it, continue to push the button up or down
until you have reached your desired setting. Again, after 3 seconds the
display will revert to showing the current room humidity.
Continuous Mode: If you want your unit to run continuously, select
a fan speed level. (Do not set your humidistat.) It will run at your
selected speed until you shut it off or it runs out of water.
NOTE: Turn the humidifier off if the humidity level feels too moist
or you notice condensation forming on the walls.
STEP 3: TIMER CONTROL
• You can set your timer for up to 18 hours. This function should only
be used if you desire that the humidifier be automatically shut off
after a certain period of time.
• Press the Timer button ( ) up or down to set how many hours you would like the humidifier to run
(Fig. 12).
• When the display indicates your desired time, wait 3 seconds.
After 3 seconds, your desired time is set and the display will revert back to showing the current room
humidity.
NOTE: If you wish to change your timer setting or check to see how much time is left, simply press the
Timer button ( ) once and it will show you the time left. If you want to change the time remaining,
continue to push the button up or down until you have reached your desired time. Again, after 3 seconds
Digital EasySet
Control Operation (Model HCM-6012i)
Fig. 10
Fig. 11
Fig. 12
Humidistat
Control
Fan Speed
Control
Timer
Control
Desired
Humidity
Light
Ionizer
Button
QuietCare_Console_OM_Rev1.qx 8/25/06 1:32 PM Page 8