Wiring
1. Run a 3-conductor thermostat cable (up to
18 gauge) from the W8600F to the terminal strip on the
air cleaner.
IMPORTANT
Connect cable to W8600F before attaching to the air
cleaner terminals to minimize the risk of damage
due to static electricity.
2. Connect the wires to terminals 1, 3 and 4 on the
W8600F. See Fig. 10.
3. Check that the battery is correctly installed in the
W8600F battery holder.
4. Snap the W8600F onto the base.
5. Turn off the power for the EAC.
WARNING
Electric Shock Hazard.
Can cause electrical shock or equipment damage.
Disconnect EAC power and open the access door
before opening the power supply box cover.
6. Open the power supply box cover.
7. Remove the plug from the side of the power supply box
(plug can be a metal knockout or a blank terminal strip).
8. Install the terminal block/cable assembly supplied with
W8600F kit.
9. Plug the connector on the end of the cable assembly
into the J2 terminal on the driver board (included with
W8600F kit). See Fig. 11.
M11970
ELECTRONIC AIR CLEANER
S
Y
S
T
E
M
J2
J1
DRIVER
BOARD
TERMINAL
STRIP
MOUNTING
SCREW
POWER SUPPLY BOX
POWER SUPPLY
BOX COVER
POWER
SUPPLY
Fig. 11. Installing the driver board on the EAC.
10. Plug the driver board assembly into the J1 power
supply connector.
11. Replace the power supply box cover.
12. Connect the three wires from the W8600F to the EAC
terminals 1, 3 and 4. See Fig. 12.
M11974
TERMINAL STRIP
ON POWER BOX
THREE-WIRE
THERMOSTAT CABLE
GREEN
RED
BLUE
1
2
3
4
G
Y
R
B
1
1 CONNECT TO W8600F TERMINALS BEFORE CONNECTING TO
POWER BOX.
ELECTRONIC AIR CLEANER
W8600F
1
3
4
Fig. 12. Wiring W8600F t F58F power box terminal strip.
NOTE: Connect terminal 1 to 1, 3 to 3 and 4 to 4.
13. Tu rn on the EAC power.
14. Tu rn on the system fan.
15. Push the W8600F reset button. All four indicators on the
display will flash 5 times. The ON indicator will stay
active as long as the EAC is on. See Fig. 13.
M15586
O
n
B
a
tte
ry
S
e
rv
ic
e
F
a
u
lt
A
ir C
le
a
n
e
r M
o
n
ito
r
Fig. 13. Complete T8600/W8600F installation.
Seal Joints
Seal all joints in the return air system between the air
cleaner and the furnace to prevent dust from entering the
clean airstream. Use optional air cleaner cabinet gasket kit
(part #32002109-001). Plastic or foil tape.
Disable Unused Prefilter Guide
Crimp the end of the downstream (closest to the furnace)
prefilter guide to prevent incorrect prefilter installation
following cleaning. See Fig. 14.