F300E ELECTRONIC AIR CLEANER
68-0240-1
8
Fig. 7. Connect ductwork to air cleaner. Note
turning vanes. Locking pliers hold duct to air
cleaner cabinet during installation.
Install Optional W8600F Air Cleaner Monitor
The W8600F Air Cleaner Monitor is an option available for
use with the F300E.
The W8600F function indicator panel has four liquid crystal
display (LCD) arrowheads that point to ON, BATTERY,
SERVICE or FAULT. See Fig. 8. The arrowheads darken to
indicate the existing EAC condition. See Table 3.
Table 3. Description of W8600F
Function Indicator Panel.
ON
BATTERY
SERVICE
FAULT
Air Cleaner Monitor
FUNCTION
INDICATOR
PANEL
LCD
RESET BUTTON
M11965
W8600F Location
The styling of the W8600F is designed to blend with the
latest T8600 family of Honeywell Chronotherm® IV Deluxe
Programmable Thermostats. A special mounting template is
included for mounting next to the T8600. The W8600F can
also be mounted at any other convenient location in the
living area or equipment room.
NOTE: The W8600F shares no electrical connections
with the thermostat.
Mounting
The following mounting instructions assume that the W8600F
is mounted next to a T8600 Thermostat. If installing the
monitor at another location, modify the procedure to fit the
installation.
1. Hold the mounting template (included in the bag
assembly) next to the T8600 as shown in Fig. 9.
2. Mark the holes for the screw anchors and the
3-conductor thermostat cable.
3. Remove the template and drill the holes.
4. Remove the W8600F from the base.
5. Position the W8600F base over the holes and install
the anchors and screws. Tighten the screws until the
base is mounted firmly on the wall.
M11971
THERMOSTAT
WALLPLATE
MOUNTING
TEMPLATE
MOUNTING HOLES
(
2
)
WIRING HOLE
M14735
LOCKING
PLIERS
TURNING
VANES
S
Y
S
T
E
M
Fig. 8. W8600F Air Cleaner Monitor features.
Fig. 9. Positioning mounting template.
Indicators Condition
ON EAC is powered and system blower is
running.
BATTERY Battery that maintains W8600F memory is
low and needs to be replaced.
SERVICE EAC prefilter and cells need to be washed
.
FAULT • Shorting of collector plates.
• Continuous ionizer or collector plate
arcing.
• Power supply failure.
• Excessive current.
• Major reduction in high voltage.
• EAC prefilter and cells are past
SERVICE level of dirt and need to be
washed immediately.
Call a service technician.