Parts and Accessories Not Illustrated
ELECTRICAL TROUBLESHOOTING
WARNING
Electric Shock Hazard.
Can cause personal injury or equipment damage.
The following procedures expose hazardous live
parts. Disconnect from power between checks and
proceed carefully. These instructions are for use by
qualified personnel only.
Tools and Equipment
Troubleshooting the electronic air cleaner requires:
Needle nose pliers for stringing ionizer wires and
inserting edge connectors.
Test meter.
Neon Light (On Power Box)
The neon light is powered through the power supply and is
on when the power supply output voltage is normal.
FAULT Indicator (Air Cleaners with W8600F)
The FAULT indicator is on the W8600F. It activates to
indicate the following conditions: excessive dirt loading,
partial shorting of the collector, continuous ionizer or
collector arcing, power supply failure, excessive ionizer
current, or any condition causing a major reduction in high
voltage.
Power Box
WARNING
Electric Shock Hazard.
Can cause personal injury.
Always turn off power and remove access door
before removing power supply or its cover.
The solid state power supply within the power supply box
can be replaced. When troubleshooting indicates a power
supply problem, replace the entire power box or replace the
power supply within the box. See Installation Instructions.
See Fig. 24 for power box removal.
Troubleshooting Procedure
The electronic air cleaner Troubleshooting charts show how
to quickly isolate a problem in the air cleaner. Although a
meter is needed for some steps, the primary diagnostic tool
is the neon light. See Fig. 28.
Nominal Return Air Opening
Description
16 x 20 in.
(406 x 508 mm)
16 x 25 in.
(406 x 635 mm)
20 x 20 in.
(508 x 508 mm)
20 x 25 in.
(508 x 635 mm)
Air Cleaner Cabinet Gasket Kit 32002109-001 32002109-001 32002109-001 32002109-001
Ionizer Wires (multiples of 5) 136434BA 136434BA 136434AA 136434AA
Mounting Screws 136375 (6) 136375 (6) 136375 (6) 136375 (6)
Air Cleaner Monitor
(beige color)
W8600F1008 W8600F1008 W8600F1008 W8600F1008
Premier White®
AIRWATCH® Indicator
W8600A1007 W8600A1007 W8600A1007 W8600A1007
Premier White® Air Cleaner Monitor W8600F1014 W8600F1014 W8600F1014 W8600F1014
2-Stage EAC Cell with
Collector Clip
N/A FC37A1247 (2) N/A FC37A1239 (2)
240V Conversion Kit 203365A 203365A 203365A 203365A
(#) = Quantity required per unit N/A = Not available as merchandized part.