10. Plug the driver board assembly into the J1 power
supply connector.
11. Replace the power supply box cover.
12. Connect the three wires from the W8600F to the EAC
terminals 1, 3 and 4. See Fig 12.
The W8600A function indicator panel has four liquid crystal
display (LCD) arrow indicators that point to Battery, Air
Cleaner, UV Air Treatment, and Humidifier. See Fig. 14. The
blinking arrowheads indicate the devices that need service.
See Table 5.
Table 5. W8600A.
M11974
TERMINAL STRIP
ON POWER BOX
THREE-WIRE
THERMOSTAT CABLE
GREEN
RED
BLUE
1
2
3
4
G
Y
R
B
1
1 CONNECT TO W8600F TERMINALS BEFORE CONNECTING TO
POWER BOX.
ELECTRONIC AIR CLEANER
W8600F
1
3
4
Fig. 12. Wiring W8600F to F300E power box
terminal strip (two-cell model).
NOTE: Connect terminal 1 to 1, 3 to 3 and 4 to 4.
13. Turn on the EAC power.
14. Turn on the system fan.
15. Push the W8600F reset button. All four indicators on
the display will flash 5 times. The ON indicator will stay
active as long as the EAC and system fan are on. See
Fig. 13.
Fig. 14. W8600A AIRWATCH Indicator features.
Set DIP Switches
1. Set then DIP switches according to equipment
installed in the home:
a. Use default position set at the factory when
alldevices (air cleaner, UV air treatment system,
humidifier) are installed in the home.
b. Move DIP switch to left (off position) when adevice
is not installed in the home.
M15586
O
n
B
a
tte
ry
S
e
rv
ic
e
F
a
u
lt
A
ir C
le
a
n
e
r M
o
n
ito
r
Fig. 13. Complete T8600/W8600F installation.
OR Install Optional W8600A-1007
AIRWATCH Indicator
The W8600A AIRWATCH Indicator is an option available for
use with the F300E. It is a battery-operated timer. Installation
only requires drilling holes in the wall to mount the device.
Battery
TM
Air Cleaner
UV Air Treatment
Humidifier
Honeywell.com/yourhome
FUNCTION
INDICATOR
PANEL
LCD
RESET BUTTON
M14696
NOTE: The W8600A beeps whenever an arrow is blinking
to alert you to identify the device that needs
service. After servicing, press the reset button at
the botton of the W8600A and hold for 10 seconds
to reset the timer.
LCD
If arrow is flashing
or unit
is beeping...
Rset by...
Battery Batteries need
changing
Changing batteries
within 30 seconds of
removing old
batteries to maintain
correct indication
time.
Air Cleaner Media filter needs
replacing or
electronic filter
needs washing.
Pressing and holding
reset button for 10
seconds or until
arrow is no longer
displayed.
UV Air
Treatment
UV lamps need
replacing in UV air
treatment system.
Humidifier
Humidifier pad