Honeywell 8000 Thermostat User Manual


 
7 62-0266—01
0535 Temporary
Occupied
Duration
Limit
3 0—no duration
1—one hour
2—two hours
3—three hours
4—four hours
0 means no limit
0540 Number of
Periods
4 2—2 Periods
4—4 Periods
Does not appear if
Non-programmable
is chosen.
Applies to all days
of the week. With 2
selected the
“Cancel Period”
option does not
appear on the
display.
0580 Minimum
Compressor
Off Time
50Off
2—2 minutes
3—3 minutes
4—4 minutes
5—5 minutes
Only shown if
system has cool
stages.
0600 Heat
Temperature
Range Stops
90 40 to 90° F (4 to 32° C) Only shown if
system has heat
stages.
0610 Cool
Temperature
Range Stops
50 50 to 99° F (10 to 37° C) Only shown if
system has cool
stages.
0640 Clock
Format
12 12—12 Hour
24—24 Hour
0650 Extended
Fan-on time
Heat
00Off
90—90 seconds
Not displayed with
fan set to fossil or
with cool-only
systems
0660 Extended
Fan-on time
Cool
0 0—Off
40—40 seconds
Only shown if
system has cool
stages.
Table 1. Installer Setup (Continued).
Installer
Setup
Number
Installer
Setup
Name
Default
Setting All Settings Notes