Honeywell 8000 Thermostat User Manual


 
5 62-0266—01
0230 CPH for
second
stage
compressor
3 1-6 Only shown if two
stages of cool
selected.
0240 CPH for first
stage
conventional
heat
5 1-12 Only shown if
system is
conventional with
heat stages.
Selection in this
stage changes
default CPH of
second stage heat.
0250 CPH for
second
stage
conventional
heat
9 1-12 Only shown with at
least two stages
conventional heat
or 2H/1C heat
pump selected.
0260 CPH for third
Stage Heat
9 1-12 Only shown if 3H/
2C heat pump is
selected.
0270 CPH for
Auxiliary
Heat
9 1-12 Only shown if multi-
stage heat pump is
selected (heat
pump with more
heat than cool
stages).
0280 Continuous
Backlight
0 0—No
1—Yes
Always shown. If
AC power not
present the option
is overridden and
normal backlight
operation occurs.
0300 Changeover 1 0—Manual
1—Auto
Only shown if
system has both
heat and cool
stages.
0310 Deadband 3° F
(2° C)
2 (1.5)—2° F (1.5° C)
3 (2.0)—3° F (2.0° C)
4 (2.5)—4° F (2.5° C)
5 (3.0)—5° F (3.0° C)
6 (3.5)—6° F (3.5° C)
7 (4.0)—7° F (4.0° C)
8 (4.5)—8° F (4.5° C)
9 (5.0)—9° F (5.0° C)
Only shown if
Automatic
Changeover
Selected
Table 1. Installer Setup (Continued).
Installer
Setup
Number
Installer
Setup
Name
Default
Setting All Settings Notes