Honeywell 3-144 Home Security System User Manual


 
31
Access Authorization (User Type 3.6)
Menu Option 48 allows access to be authorized for engineers for system
programming and for managers in order to add/delete/change all user
codes.
1 = Engineer
The engineer code is assigned programmed as dual by default. This
prevents the engineer from accessing engineer mode unless authorized
to do so by a valid code. To gain access to the engineer menu a type 3.6
user must enter their code, and enable the Engineer Access option. This
provides a five minute period during which a single entry of the engineer
code provides access to engineering mode without causing a tamper
alarm. Once the engineer mode has been accessed, there is no time limit
on the access period.
If the Engineer Mode option has not been enabled, or the code is not
entered within the five minute period, then the Engineer code is invalid
and has no effect.
If the PIN is programmed without the #, the Engineer Access option
does not require to be enabled to allow the engineer to gain access to
engineer mode. The engineer code requires to be entered twice. The first
entry activates a tamper alarm which is cancelled by the second entry.
NOTE: Dual entry of the engineer code in a system requiring user
authorization does not give access to engineer mode.
2 = Manager
This option allows type 3.6 manager codes to be enabled for user code
adding/deleting/changing. This option can only be enabled by the au-
thorization code. However, this option is not used by default. Manager
codes are always authorized. It can be enabled, if required, to comply
with standards in certain regions. An authorization code must be as-
signed in Menu 42 Codes, before the function is enabled.