Appendix: Installation
Figure 14
3.5 Wiring
(1)Before wiring, make sure the rated voltage indicated on the
nameplate conforms to the local power voltage.
(2)Wiring should be carried out in accordance with the
instructions on the electrical schematic diagram (Figure 14).
1
2
3
Terminal
Panel of
the indoor
unit
Terminal
Panel of
the outdoor
unit
!
WARNING
Wiring for connection of the indoor unit and the outdoor unit
should be conducted in accordance with local regulations.
Wiring connections must be fitted firmly.
The electrical wires should not be in contact with any of the
refrigeration tubes, compressor or other moving parts or
components.
The appliance must be connected to a good earth.
3.6 Wiring connection of the indoor unit
1) Hold pull and open the front cover.
2) Release the screws and open the wire distribution cover
(Figure 15).
Figure 15
Wiring distribution
cover
Wiring distribution
cover
3) Connecting cable should be placed along the back of the
indoor unit to the front for connection.
4)Connect the wire distribution terminals and corresponding
terminals .(Figure 16)
Figure 16
Figure 17
5) Check the connections and then fasten the distribution
cover and replace the front cover finally.
4. INSTALLATION OF THE OUTDOOR UNIT
Properly locate the outdoor unit as described by the Section 2.
If the outdoor unit is to be mounted on the wall ,make sure that
the wall and the support are strong enough for the appliance.
Wiring Connection
1) Release the fixing screws and take off the side cover.
2) Connect the terminals on the heap pump as required in the
Figure 14 and the Figure 17:
3) Always save an extra 10cm length of the electrical cable:
4) Earth the appliance according to related regulations of
electrical engineering:
5) Fix the connected terminals with clips and replace the side
cover if the connection is assured according to the wiring
diagram: