Heatiator ECO-ADV-WS22 Stove User Manual


 
20
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
4

Withproperinstallation,operation,andmaintenanceyourwoodstovewillprovideyearsoftrouble-freeservice.Ifyoudo
experienceaproblem,thistroubleshootingguidewillassistyouoraqualiedservicepersoninthediagnosisofaproblem
andthecorrectiveactiontobetaken.
  Solution
Cannotgetrestarted
Excessivesmokeorspillage
Burnstooslowly
Notenoughheatoutput
Notenoughkindling/paperorno
kindling/paper
Usedrykindling,morepaper.Arrangekindling&
woodforairmovement.
Notenoughairforretoignite
Checkforrestrictedterminationcap
Checkforblockageofoutsideairkit(ifinstalled).
Checkforueblockage.
Pre-warmuebeforestartingre(refertoBuilding
aFireSection).
Checkforadequateventheight(refertoChimney
HeightSection).
Openwindowbelowtheappliancetowardsthe
wind.
Woodconditionistoowet,too
large
Usedry,seasonedwood(refertoSeasonedWood
Section).
Bedofcoalsnotestablished
beforeaddingwood
Startwithpaper&kindlingtoestablishbedof
coals(refertoBuildingaFireSection).
Flueblockagesuchasbirds’
nestsorleavesintermination
cap
Havechimneyinspectedforcreosoteandcleaned
byacertiedchimneysweep.
Downdraftornegativepressure
Competitionwithexhaust
devices
Donotuseexhaustfansduringstart-up(referto
NegativePressureSection).
Openwindowbelowtheappliancetowardsthe
wind.
Fireburnstoofast
Extremelydryorsoftwood
Mixinhardwood.
Mixinlessseasonedwoodafterreisestablished
(refertoWoodFuelSection).
Overdrafting
Checkforcorrectventheight;toomuchvertical
heightcreatesoverdrafting.
Checklocationofventtermination(referto
ChimneyTerminationRequirementSection).