14
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
7.
Ifyoundtheblowercomingonandoffatundesirable
temperatures,relocatethesnapdisctoanotherlocation
inthedesignatedzoneon thebackoftheappliance.
There is a manual over-ride switch to
deactivatethesnapdisc,ifnecessary.
forlocationofover-rideswitch.
Blower
Snap Disc
N
• DoNOTplacecombustibleobjectswithin4ft(1.2m)of
thefrontofappliance.See.
WARNING! DoNOTplacecombustibleobjectsinfront
oftheappliance. Hightemperaturesmayigniteclothing,
furnitureordraperies.
• Mantel-avoidplacingcandlesandotherheat-sensitive
objects onmantel or hearth. Heat may damage these
objects.
NOTE:Ifyourwoodapplianceisequippedwithanoptional
blower,youshouldfollowtheseguidelines:
Burn Rate
Air Control
Handle Up = Open
Handle Down = Closed
Maintain 4 ft. (1.22m) clearance to
combustible in front of appliance
1.RaisetheBurnRateAirControl
allthewayuptotheHighsetting.
Theblowertendsto
cooltheappliance.Leavethebloweroffuntiltheburnis
wellestablished,i.e.,30minutes.
2 RaisetheBurnRateAirControlall
thewayuptotheHighsetting.Theblowermayremain
on.
3. BurnRateAir
Controlisclosedthenopenedto1inch(pullup).The
blowermayremainon.
4. MediumBurnRateAirControlis
closed then opened to 1/4 inch to 1/2 inch (pull up).
Leavetheblowerofffortherst30minutesuntiltheburn
iswellestablished.
5. Burn Rate Air Control is closed
(downposition).
Leavetheblowerofffortherst30min-
utesuntiltheburniswellestablished.
NOTE: Formaximumefciencyandlowestemissions,
when operating the blower in either the automatic or
manualsettingforthelowandmediumlowburnsettings
leavethebloweroffuntiltheburniswellestablished,i.e.,
30minutes,
When reloading the appliance, raise the Burn RateAir
ControlallthewalltotheHighsettingfor5to15minutes
beforesettingtothedesiredburnrate.
6. Theblowerisequippedwitharheostat(speedcontrol).
The highest blower speed is obtained by turning the
rheostaton, thenadjustingback towards“OFF”asfar
as possible without turning the blower off. For a low
blowerspeed,turnthecontrolknobclockwiseasfaras
possible