M. Wood Fuel
Hardwood vs Softwood
Your replace performance depends on the quality of the
rewood you use.
Seasoned wood contains about 8,000 BTUs per
pound.
Hard woods are more dense than soft woods.
Hard woods contain 60% more BTUs than soft woods.
Hard woods require more time to season, burn slower
and are harder to ignite.
Soft woods require less time to dry, burn faster and are
easier to ignite.
Start the re with soft wood to bring the replace up to
operating temperature and to establish draft.
Add hard wood for slow, even heat and longer burn
time.
The majority of the problems replace owners experience
are caused by trying to burn wet, unseasoned wood.
Wet, unseasoned wood requires energy to evaporate
the water instead of heating your home, and
Evaporating moisture cools your chimney, accelerating
formation of creosote.
WARNING! Risk of Fire!
DO NOT burn wet or green wood.
Wet, unseasoned wood can cause accumulation of
creosote.
Moisture
Soft woods Hard woods
Douglas Fir Oak
Pine Maple
Spruce Apple
Cedar Birch
Poplar
Aspen
Alder
Storing Wood
Steps to ensure properly seasoned wood:
Stack wood to allow air to circulate freely around and
through woodpile.
Elevate wood pile off ground to allow air circulation
underneath.
Smaller pieces of wood dry faster. Any piece over 6 in.
(152 mm) in diameter should be split.
Wood (whole or split) should be stacked so both ends
of each peice are exposed to air. More drying occurs
through the cut ends than the sides.
Store wood under cover to prevent water absorbtion
from rain or snow. Avoid covering the sides and ends
completely.
Seasoned Wood
Cut logs to size
Split to 6 in. (152 mm) or less
Air dry to a moisture content of around 20%
- Soft wood - about nine months
- Hard wood - about eighteen months
NOTICE: Seasoning time may vary depending on drying
conditions.
WARNING! Fire Risk! DO NOT store wood:
In front of the replace.
In space required for loading or ash removal.
Processed Solid Fuel Firelogs
Manufactured relogs may be used with this replace.
Hearth & Home Technologies Inc. recommends the use of
UL Classied processed fuel relogs. Follow the manufac-
turer’s lighting and safety instructions.
Using relogs may require more frequent chimney inspec-
tion and cleaning.
Do not poke or stir the logs while they are burning. Use
only relogs that have been evaluated for the application
in manufactured replaces and refer to relog warnings
and caution markings on packaging prior to use.
Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12